Blog navigation

Latest posts

Deye SUN 6K vs 10K vs 15K : quelle puissance choisir selon votre usage ?
Deye SUN 6K vs 10K vs 15K : quelle puissance choisir selon votre usage ?
533 views

Expert comparison of the Deye SUN 6K, 10K and 15K hybrid inverters: power output, battery compatibility, three-phase...

Deye SUN 6K vs 10K vs 15K : quelle puissance choisir selo...
Deye Cloud 4.3: the AI that manages your solar battery (2026)
Deye Cloud 4.3: the AI that manages your solar battery (2026)
1517 views

Discover Deye Cloud 4.3: the intelligent Copilot mode, real-time notifications and Deye Wise AI, which are...

Deye Cloud 4.3: the AI that manages your solar battery (2...
MQTT + Deye: 2 ways to integrate your inverter into your home automation system
MQTT + Deye: 2 ways to integrate your inverter into your home automation system
3584 views

Find out how to send data from your Deye inverter (SUN-5K, 8K, 12K, 20K) to your MQTT home automation system (Home...

MQTT + Deye: 2 ways to integrate your inverter into your ...
V2L vers V2H avec Deye : le hack, le schéma et les limites
V2L vers V2H avec Deye : le hack, le schéma et les limites
1931 views

Peut-on transformer un véhicule compatible V2L en pseudo-V2H avec un onduleur hybride Deye ? Oui, dans certains cas,...

V2L vers V2H avec Deye : le hack, le schéma et les limites
Performance agrivoltaïsme : l’essentiel IEA PVPS
Performance agrivoltaïsme : l’essentiel IEA PVPS
1394 views

L’agrivoltaïsme suscite beaucoup de prises de position, mais beaucoup moins de lectures techniques sérieuses. Ce...

Performance agrivoltaïsme : l’essentiel IEA PVPS

Technical Guides

The electrical aspects of a photovoltaic installation require rigour and compliance with standards to ensure the safety of people and property. Sizing of protective devices, choice of cable cross-sections, and earthing are all crucial technical steps.

This sub-category includes all electrical technical guides: circuit breakers and AC/DC protection, cable cross-section calculation, single-line diagrams, earthing and lightning protection, compliance with NF C 15-100 standards and UTE C 15-712-1 guide.

The Definitive Guide to Circuit Breakers 2026. Our comprehensive reference (116 views) explains everything: circuit breaker ratings according to nominal circuit current, B/C/D curves and their applications (B for residential, C for inductive loads, D for motors), AC sizing (panel circuits → inverter → grid), and DC sizing (PV strings, batteries). Summary tables for 3kWp, 6kWp and 9kWp installations.

Cable cross-sections: essential calculations. The voltage drop must not exceed 3% in DC and 1% in AC. Formulas: Cross-section (mm²) = (2 × Length × Current) / (Conductivity × Permissible voltage drop). Examples: 10A string over 20m → minimum 4mm² copper. 100A battery-inverter connection over 1m → minimum 25mm².

You will also learn about earthing (equipotential bonding of panel frames, Type 2 lightning protection), regulatory signage (DC labels, emergency cut-off) and Consuel procedures for compliant commissioning.

 