Belgium's saturated electricity grid: the myth of all-electricity revealed
Belgium's saturated electricity grid: the myth of all-electricity revealed
160 views

ORES rejects 27 high-voltage substations and warns of 10,000 vulnerable circuits. The much-vaunted PV + heat pump duo...

Read more
Solarman : Comment utiliser l'application pour surveiller votre onduleur ?
Solarman : Comment utiliser l'application pour surveiller votre onduleur ?
56 views

Maîtrisez l'application SOLARMAN Smart pour piloter et surveiller votre onduleur depuis votre smartphone ou PC en...

Read more
Groupe électrogène de Secours : Comment l'Automatiser avec Victron, Deye & WKS
Groupe électrogène de Secours : Comment l'Automatiser avec Victron, Deye & WKS
51 views

Guide expert pour le démarrage automatique de groupe électrogène (AGS). Comparatif des configurations sur Victron...

Read more
All-in-One (Zendure, EcoFlow) vs Modulaire (Deye, Victron) : Quel Kit Solaire choisir ?
All-in-One (Zendure, EcoFlow) vs Modulaire (Deye, Victron) : Quel Kit Solaire choisir ?
213 views

Systèmes all-in-one (Zendure, EcoFlow, Bluetti, Marstek) vs modulaires (Deye, Victron + Pylontech) : comparatif...

Read more
Le Guide Définitif des Disjoncteurs 2026 : Dimensionnement AC/DC
Le Guide Définitif des Disjoncteurs 2026 : Dimensionnement AC/DC
282 views

Guide complet sur les disjoncteurs électriques : calibre, courbes B/C/D, sections de câbles, dimensionnement AC/DC...

Read more

Technical Guides

The electrical aspects of a photovoltaic installation require rigour and compliance with standards to ensure the safety of people and property. Sizing of protective devices, choice of cable cross-sections, and earthing are all crucial technical steps.

This sub-category includes all electrical technical guides: circuit breakers and AC/DC protection, cable cross-section calculation, single-line diagrams, earthing and lightning protection, compliance with NF C 15-100 standards and UTE C 15-712-1 guide.

The Definitive Guide to Circuit Breakers 2026. Our comprehensive reference (116 views) explains everything: circuit breaker ratings according to nominal circuit current, B/C/D curves and their applications (B for residential, C for inductive loads, D for motors), AC sizing (panel circuits → inverter → grid), and DC sizing (PV strings, batteries). Summary tables for 3kWp, 6kWp and 9kWp installations.

Cable cross-sections: essential calculations. The voltage drop must not exceed 3% in DC and 1% in AC. Formulas: Cross-section (mm²) = (2 × Length × Current) / (Conductivity × Permissible voltage drop). Examples: 10A string over 20m → minimum 4mm² copper. 100A battery-inverter connection over 1m → minimum 25mm².

You will also learn about earthing (equipotential bonding of panel frames, Type 2 lightning protection), regulatory signage (DC labels, emergency cut-off) and Consuel procedures for compliant commissioning.

 