Schneider Acti9 Circuit Breaker - 2P - 50A - C Curve - 400V - A9F64250

Schneider Acti9 Circuit Breaker - 2P - 50A - C Curve - 400V - A9F64250

CHF54.87
Tax included
A9F64250
0712971137578

The Acti9 A9F64250 two-pole circuit breaker simultaneously protects the phase and neutral of your residential, commercial or small industrial electrical circuits. With a rating of 50A and a type C trip curve, it is suitable for sockets, lighting, small motors and AC auxiliary circuits in photovoltaic installations.

Its magnetothermal technology combines thermal protection (against overloads) and magnetic protection (against short circuits up to 500A). Its breaking capacity is 10 kA at 400V AC, guaranteeing safety and reliability.

The 36 mm modular circuit-breaker is easy to install on 35 mm DIN rail, with terminals accepting cables up to 25 mm². It offers high durability (20,000 mechanical cycles, 10,000 electrical cycles) and IP20 protection.

Ideal for: domestic and tertiary circuits, AC photovoltaic circuits, small single-phase motors and general switchboard protection.

Circuit breaker Schneider Acti9 - 2P - 50A - C-curve - 400V - A9F64250


The Schneider Acti9 A9F64250 modular circuit breaker is a 2-pole, 50-amp electrical protection device designed to protect your residential, commercial and small industrial circuits. Certified to IEC 60898-1, this thermal-magnetic device combines robustness, reliability and easy installation to guarantee the safety of your electrical installations.






Complete two-pole protection for your electrical circuits

This 2-pole 2P circuit breaker simultaneously protects phase and neutral, ensuring complete circuit breaking in the event of an overload or short-circuit. With its 50 amp rating and type C tripping curve (magnetic tripping 5 to 10 times the rated current), it's ideal for circuits including sockets, lighting, small single-phase motors and domestic or commercial equipment.

The breaking capacity is 10 kA at 400V AC, guaranteeing effective protection even in environments where short circuits can generate high currents. The rated voltage of 400V AC (insulation voltage 440V AC) allows safe use in single-phase or light three-phase.






Schneider Electric magnetothermal technology

The mechanism incorporates a dual thermal and magnetic protection system:

  • Thermal protection (bimetallic strip): progressive tripping in the event of prolonged overload (1.13 to 1.45 In), effectively protecting the cables against overheating.
  • Magnetic protection (coil): instantaneous tripping (< 10 ms) in the event of a short-circuit (5 to 10 times the rated current), i.e. between 250A and 500A for this 50A model.

This dual protection guarantees safety and reliability, while limiting nuisance tripping thanks to the C curve adapted to moderate resistive and inductive loads.






Compatible applications and circuits

Application Recommended cable cross-section Notes
Lighting and domestic/tertiary sockets 6 mm² Cu Circuits up to 50A
Small single-phase motors 10 mm² Cu Compatible with motors ≤ 5.5 kW
Photovoltaic AC auxiliary circuits 6 to 10 mm² Cu For meters, monitoring, BMS and auxiliaries
Small light industrial circuits 6 to 10 mm² Cu Sockets and non-motorised electrical equipment



NF C 15-100 and RGIE compliance: The 50A circuit-breaker is suitable for copper cables with a current-carrying capacity ≥ 50A. The rating remains lower than the cable's current-carrying capacity, ensuring optimum protection in accordance with current standards.






AC protection in photovoltaic systems

In photovoltaic systems, the Acti9 A9F64250 provides effective protection for AC circuits:

  • Power supply for energy meters and monitoring systems
  • Control and signalling circuits
  • Battery management system (BMS) power supply
  • Auxiliary UPS circuits

For main protection on the AC side of the UPS, opt for our higher-calibre circuit breakers.






Easy installation on 35 mm DIN rail

The compact 36 mm wide modular format (2 x 18 mm modules) allows easy installation in standard switchboards. Mounting on 35 mm DIN rail is a simple snap-in operation. The screw terminals accept rigid and flexible copper conductors up to 25 mm² with a recommended tightening torque of 2 Nm.






Schneider Electric reliability and durability

  • Mechanical life: 20,000 open/close cycles
  • Electrical life: 10,000 cycles at rated load
  • Limitation class: Class 3
  • Degree of protection: IP20 (device only), IP40 with modular cover
  • Operating temperature: -25°C to +70°C






Detailed technical specifications

Characteristic Value
Manufacturer reference A9F64250
Brand Schneider Electric
Range Acti9 iC60a
Type Miniature circuit breaker (MCB)
Configuration 2P (two-pole, 2-pole protected)
Rated current (In) 50 A at 30°C
Tripping curve C (general use)
Magnetic threshold 8 × In ± 20% (350-440 A)
Breaking capacity (Icn) EN 60898-1 4500 A at 400V AC 50/60 Hz
3000 A at 230V AC 50/60 Hz
Breaking capacity (Icu) EN 60947-2 10 kA at 220-240V AC 50/60 Hz
6 kA at 380-415V AC 50/60 Hz
Service breaking capacity (Ics) 100% of Icu according to EN 60947-2
Limiting class 3 according to EN/IEC 60898-1
Rated voltage (Ue) 220-240V AC 50/60 Hz (single-phase)
380-415V AC 50/60 Hz (phase-to-phase)
Insulation voltage (Ui) 500 V AC 50/60 Hz
Impulse withstand voltage (Uimp) 6 kV
Frequency 50/60 Hz
Tripping technology Thermal-magnetic
Standards EN/IEC 60898-1
EN/IEC 60947-2
Category of use Category A to EN 60947-2
Isolating capability Yes to EN 60898-1 and EN 60947-2
Fully apparent breaking Yes
Certification CE, CEBEC
Number of modules (9mm) 4 modules (36 mm total)
Mounting 35 mm DIN rail, clip-on
Protection class IP20 (front)
Control type Tilting lever
Signalling Visual trip indicator
Bollard type Single tunnel terminal (top or bottom)
Section of rigid cable 35 mm² max.
Flexible cable section Max. 25 mm² conductor cross-section
Stripping length 14 mm
Tightening torque 3.5 Nm (top or bottom)
Operating temperature range -25°C to +70°C
Storage temperature -40°C to +85°C
Mechanical life 20,000 cycles
Electrical life 10,000 cycles at In
Dimensions (H×W×D) 85 × 36 × 78.5 mm
Weight ≈ 0.250 kg
Colour White






Why choose Wattuneed?

  • Original Schneider Electric products with manufacturer's warranty
  • Expert technical advice to size your protections
  • Fast delivery in Belgium and France
  • Permanent stock of electrical and photovoltaic equipment
  • Full technical documentation available online






Technical documentation and resources

To find out more about choosing and sizing circuit breakers, consult our complete guide to circuit breakers. Our technical team is available via our support service to help you design your electrical switchboards.

A9F64250

Data sheet

Type of electrical equipment
Disjoncteur

Specific References

UPC
712971137578
EAN13
0712971137578
New
Loading...