Current clamp 120A/40mA
Current clamp 120A/40mA
Current clamp 120A/40mA

120A/40mA ammeter clamp for Sofar Solar inverters

€60.50
Tax included
Pa-120A-40mA
0768563822193

The 120A/40mA current clamp is a high-precision current sensor that is essential for smart energy management. This product is a current transformer (CT) used to measure the intensity of the electrical flow in your installation without interrupting the circuit.

This accessory is specifically compatible with Sofar Solar inverters, particularly the single-phase and three-phase hybrid ranges. This device measures grid injection and household consumption, integrating seamlessly with the manufacturer's native monitoring system.

With a ratio of 120A/40mA, this clamp ensures accurate data readings, which are essential for activating zero feed-in functions or optimising the charging and discharging of storage batteries. It is easy to install by clipping it around the main phase conductor.

Main technical advantages:

  • High precision: Calibrated transformation ratio for detailed analysis of active power.
  • Quick installation: Split Core system allowing installation without disconnecting existing cables.
  • Guaranteed compatibility: Developed to work natively with Sofar Solar communication protocols.
  • Safety: Reinforced insulation for reliable integration into the main electrical panel.

Reference: CT-120A-Sofar
EAN: 0768563822193

No items in stock

120A/40mA clamp ammeter: Professional measurement for solar installations



The 120A/40mA current clamp is an essential professional measuring instrument for photovoltaic installers, electricians and maintenance technicians. This current clamp accurately measures the current flowing through a conductor without having to interrupt the circuit, providing a safe, quick and non-invasive solution for diagnosing and checking installations.






Why use a current clamp?

Unlike traditional measuring methods, which involve opening the electrical circuit and inserting an ammeter in series, current clamps work by magnetic induction. Simply wrap the jaws of the clamp around the conductor to obtain an instant reading of the current flowing through it.
This non-invasive method guarantees user safety, avoids the risk of short-circuits during measurement and enables rapid diagnostics without interrupting the operation of the installation.






Main technical features

Caractéristique Valeur
Plage de mesure maximale 120A AC
Résolution minimale 40mA
Ouverture de mâchoire 40 mm (diamètre max conducteur)
Type de courant Alternatif (AC)
Précision ± 2% de la lecture
Fréquence 50/60 Hz
Sortie Signal analogique compatible multimètre
Poids ~200g (léger et portable)






Compatibility with Sofar Solar inverters

This current clamp is specifically recommended for direct measurement on Sofar Solar single-phase inverters, enabling installers to quickly and accurately check :



  • Photovoltaic production: Measurement of the current generated by the solar panels before conversion by the inverter
  • AC output current: Checks the current fed into the grid or supplying domestic loads
  • Battery charging current: Checks the current flowing to storage batteries (ESI hybrid inverters)
  • Fault diagnosis: Rapid identification of production imbalances, overcurrents or malfunctions



Compatible Sofar Solar models :

  • ESI range (single-phase hybrid inverters) : ESI-3K-S1, ESI-4.6K-S1, ESI-6K-S1
  • ME range (single-phase grid inverters) : ME 3000 SP
  • KTLM-G3 range (single-phase mains inverters): 3KTLM-G3, 4KTLM-G3, 5KTLM-G3

To discover the full range of Sofar Solar inverters, visit our dedicated Sofar Solar brand page.






Professional applications

The 120A/40mA clamp ammeter meets the needs of professionals in many situations:



  • Commissioning solar installations: checking that production corresponds to the expected values according to the amount of sunshine and power installed
  • Preventive maintenance: Regular monitoring of currents to detect performance drifts before they cause faults
  • Fault diagnosis: Rapid pinpointing of a production problem (faulty panels, damaged cables, faulty inverter)
  • Load balancing: Measurement of consumption on different circuits to optimise power distribution
  • Conformity check: Checks that measured currents comply with standards and equipment limits
  • Technical training: Educational tool for understanding energy flows in a photovoltaic installation






Advantages of measuring with current clamps

Magnetic induction measurement technology offers a number of advantages over conventional ammeters:



  • Maximum safety: No direct electrical contact, no risk of electric shock or short-circuit.
  • Non-invasive measurement: no need to cut the circuit or disconnect cables
  • Fast: Instant reading, so you can quickly test several measurement points
  • Versatility: Suitable for domestic installations (up to 120A, more than enough for residential use)
  • Portability: lightweight and compact, easy to carry in a tool case
  • Durability: Robust construction to withstand site conditions






Use and instructions

Using a clamp ammeter is simple and intuitive:



  1. Prepare the installation: Make sure the installation is powered up and operating normally.
  2. Open the jaws: Press the clamp opening lever
  3. Wrap the conductor: Position a single conductor (phase or neutral, never both together) in the centre of the jaws.
  4. Close the jaws: Release the lever so that the jaws close completely around the cable
  5. Read the measurement: The current is displayed instantly on the multimeter or the connected display.
  6. Remove the clamp: Open the jaws again and remove the clamp from the conductor

Important: To obtain a correct measurement, it is essential to measure onlyone conductor at a time. If the phase and neutral conductors pass through the clamp together, the magnetic fields cancel each other out and the reading will be zero or incorrect.






Clamp sizing and choice

The 120A/40mA clamp is perfectly sized for residential and small commercial installations:



Type d'installation Puissance typique Courant max (230V) Compatibilité
Résidentiel monophasé 3-10 kVA 13-43A ✅ Idéale
Petit tertiaire 10-20 kVA 43-87A ✅ Parfaite
Installation solaire 3-15 kWc 13-65A ✅ Optimale
Onduleur Sofar 3-6 kW 3000-6000W 13-26A ✅ Compatible

For high-power three-phase installations or measurements requiring greater accuracy, other current clamp models may be more suitable.






Care and Precautions

To ensure the longevity and accuracy of your current clamp:



  • Cleaning: Clean the jaws regularly with a dry cloth to prevent dust build-up.
  • Storage: Store in a dry place, away from humidity and shocks.
  • Checking: Periodically check accuracy against a reference instrument
  • Jaws: Ensure that the jaws close correctly and completely to guarantee accuracy.
  • Cables: Check the condition of the connecting cables and replace them if damaged.

Safety precautions:



  • Never use on circuits exceeding 120A
  • Ensure that safety distances from live parts are observed
  • Wear appropriate personal protective equipment (insulated gloves, goggles)
  • Do not use in damp or explosive environments






Accessories and Additional Tools

Wattuneed offers a complete range ofaccessories and professional electrical equipment to optimise your measurements and diagnostics of photovoltaic installations:



  • Digital multimeters with ammeter function
  • Continuity and voltage testers
  • DC current clamps for panel-side measurement
  • Data loggers for long-term monitoring
  • Complete diagnostic kits for installers






Wattuneed resources for installers

To learn more and optimise your solar installations, check out our free resources:



Pa-120A-40mA

Specific References

UPC
768563822193
EAN13
0768563822193
Loading...