Socomec TCA21 Current Transformers - 200A/5A or 250A/5A - Class 0,5 - 2,5VA - Ø21mm
HIGH PRECISION MEASUREMENT CLASS 0.5 FOR 20-60 kW INSTALLATIONS
Socomec TCA21 class 0.5 current transformers are your allies for high-precision monitoring of your professional photovoltaic installations. Manufactured in Alsace, France, and available in two ratings (200A/5A and 250A/5A), they convert your high primary currents into a standard 5A signal with an error ≤ 0.5%, ideal for commercial metering and demanding energy management.
- Accuracy class 0.5 (±0.5%): commercial metering, high-performance PV monitoring
- Two ratings available: 200A/5A (20-45 kW) or 250A/5A (25-60 kW)
- 2.5VA power: DIRIS compatible, compact installation (CT close to power station)
- Ø21mm bore: 50-70mm² cables or 15x5mm copper bars
Manufactured in France by Socomec
Socomec TCA21 200A/5A and 250A/5A Current Transformers - High accuracy measurement class 0.5
Socomec TCA21 current transformers are professional measuring transducers designed to convert high primary currents (200A or 250A) into a standardised secondary current of 5A, suitable for DIRIS dataloggers, COUNTIS energy meters and monitoring systems. Available in two ratings (200A/5A and 250A/5A), they offer an accuracy class of 0.5 and an apparent power rating of 2.5VA, guaranteeing highly accurate measurement for your photovoltaic, tertiary and industrial installations.
A product with multiple variations
This product data sheet covers two models in the TCA21 range:
- TCA21 200A/5A (ref. 192T2020): 20-45 kW installations
- TCA21 250A/5A (ref. 192T2024): 25-60 kW installations
Both models share the same characteristics (class 0.5, 2.5VA, Ø21mm, DIN rail) and differ only in their primary rating.
Why use a current transformer in your installations?
Current transformers are essential for measuring high currents safely and accurately:
- Protection of measuring equipment: enables currents of up to 200-250A to be measured with equipment calibrated for 5A only
- Signal standardisation: standardised 5A output compatible with all dataloggers and energy meters
- Galvanic isolation: electrical separation between power circuit (primary) and measurement circuit (secondary) for maximum safety
- Cost-saving: avoids the use of expensive, heat-dissipating resistive shunts
- Standards compliance: meets IEC 61869-2 standards for energy metering and billing
Typical applications for Socomec TCA21 transformers
- Residential and tertiary photovoltaic installations: solar production measurement (AC single-phase or three-phase inverter side)
- Energy metering and billing: integration with MID meters for consumption/production monitoring
- DIRIS Socomec measurement centres: collection of electrical data (current, power, power factor, harmonics)
- Low-voltage switchboards: monitoring of main feeders and critical circuits
- EV charging stations: metering of energy delivered to high-power electric vehicles (22 kW three-phase)
- Heat pumps and large consumers: real-time consumption monitoring (15-25 kW heat pumps)
- Commercial and industrial buildings: energy management, consumption drift detection, tariff optimisation, etc.
Technical specifications
| Paramètre | TCA21 200A/5A | TCA21 250A/5A |
|---|---|---|
| Fabricant | Socomec (France) | |
| Référence fabricant | 192T2020 | 192T2024 |
| EAN-13 | 0768563818509 | |
| Gamme | TCA21 (Transformateur Courant Alésage 21mm) | |
| Type | Transformateur de courant à câble traversant (câble passant) | |
| Courant assigné primaire (In) | 200 A | 250 A |
| Courant assigné secondaire (Is) | 5 A | |
| Rapport de transformation | 200:5 (40:1) | 250:5 (50:1) |
| Classe de précision | 0,5 (erreur ≤ 0,5% pour comptage commercial) | |
| Puissance apparente nominale secondaire (Sn) | 2,5 VA | |
| Facteur de limite de surintensité (FS) | FS 5 (supporte 1000A crête) | FS 5 (supporte 1250A crête) |
| Charge secondaire max | 0,10 Ω (à 2,5VA et 5A : Z = 2,5 / 5² = 0,10Ω) | |
| Qualité diélectrique | 3 kV AC 50 Hz pendant 1 minute (isolation primaire/secondaire) | |
| Fréquence d'emploi | 50-60 Hz | |
| Surcharge permanente | 1,2 x In (240A continu) | 1,2 x In (300A continu) |
| Classe d'isolation thermique | Classe E (120°C) | |
| Diamètre d'ouverture (alésage) | 21 mm (passage câble/barre) | |
| Nombre d'entrées primaires | 1 (câble traversant simple) | |
| Fixation | Rail DIN 35mm enclipsable + pattes de fixation par vis | |
| Avec rail en cuivre | Oui (barre cuivre primaire intégrée en option) | |
| Raccordement secondaire | Connexion à vis (bornes à serrage) | |
| Cache-bornes | Oui (amovible, protection contre contacts accidentels) | |
| Court-circuit secondaire | Doubles bornes permettant court-circuitage sécurisé | |
| Dimensions (H x L x P) | 65 mm x 45 mm x 21 mm (alésage) | |
| Poids | 0,160 kg (approx.) | |
| Température de fonctionnement | -25°C à +55°C (ambiance) | |
| Degré de protection IP | IP20 (montage tableau) | |
| Normes | IEC 61869-2 (ex IEC 60044-1), EN 50160 | |
| Certifications | CE | |
| Pays de fabrication | France 🇫🇷 (Socomec Benfeld, Alsace) | |
Why choose Socomec TCA21 200A/5A and 250A/5A transformers?
1. Accuracy class 0.5: high-precision commercial metering and monitoring
Accuracy class 0.5 means that the measurement error is less than or equal to 0.5% in the current range 5%-120% In :
- ✅ Commercial metering and billing: complies with fiscal metering and energy billing requirements (class 0.5 accepted for commercial metering according to IEC 62052-11)
- ✅ High accuracy photovoltaic monitoring: ±0.5% error on 200-250A = ±1-1.25A = ±230-290W @ 230V, very low vs. weather variations
- ✅ Demanding energy management: fine detection of consumption drifts, precise tariff optimisation
- ✅ Reliable reporting: usable data for financial and technical analyses
Comparative table of accuracy classes
Classe Erreur max Application typique Surcoût 0,2S ≤ 0,2% Comptage fiscal haute précision +80-120% 0,5 ≤ 0,5% Comptage commercial, monitoring PV précis ✅ Référence 1 ≤ 1% Comptage industriel standard, monitoring PV -30% 3 ≤ 3% Protection, indication approximative -50% TCA21 class 0.5: excellent accuracy/price ratio for professional photovoltaic installations.
2. Apparent power 2.5VA: optimised for compact installations
The nominal apparent secondary power (Sn = 2.5VA) defines the maximum load supported by the CT:
- Maximum secondary load: Z_max = Sn / Is² = 2.5 / 5² = 0.10 Ω
- Compatible with compact dataloggers: typical input impedance 0.01-0.05 Ω (DIRIS Digiware, COUNTIS E)
- Acceptable secondary cable length: up to 30-40m in 2.5 mm² copper (linear resistance 7 mΩ/m)
- Installation close to the panel: 2.5VA suitable for configurations where the CT and control unit are close together (< 20m)
Comparison TCA21 (2.5VA) vs TCA22 (3.75VA)
Modèle Sn Z max Longueur câble max (2,5mm²) Usage recommandé TCA21 (Ø21mm) 2,5 VA 0,10 Ω 30-40m Installation compacte, TC proche tableau ✅ TCA22 (Ø22,5mm) 3,75 VA 0,15 Ω 50-60m Installation étendue, TC éloigné tableau Choice: If distance between CT and power station < 20m → TCA21 (more compact, less expensive). If > 30m → TCA22.
3. Two ratings suitable for power ratings of 20-60 kW
TCA21 200A/5A: 20-45 kW installations
- Single-phase PV inverters: 15-20 kW (max current 65-87A @ 230V)
- Three-phase PV inverters: 30-45 kW (max current per phase 43-65A @ 400V)
- Three-phase EV charging stations: 22 kW (current 32A per phase → comfortable margin)
- Commercial heat pumps: 15-20 kW electric
TCA21 250A/5A: 25-60 kW installations
- High-power single-phase PV inverters: 25-30 kW (max current 109-130A @ 230V)
- Three-phase PV inverters: 40-60 kW (max current per phase 58-87A @ 400V)
- Residential/tertiary switchboard feeders: circuits up to 60 kW
- Distributed generation units: cogeneration, generators, etc.
4. FS 5 overcurrent limiting factor: robustness against overloads
FS 5 guarantees that the CT withstands currents of up to 5 x In for 1 second without degradation:
- ✅ TCA21 200A/5A: withstands 1000A peak without destruction
- ✅ TCA21 250A/5A: withstands 1250A peak without destruction
- ✅ Mains short-circuit protection: typical fault current 500-2000A absorbed without destruction
- ✅ Transient overloads: motor starting, transformer inrush, inrush currents.
5. 21mm opening diameter: medium-section cables and bars
The21mm bore allows the passage of :
- Single-phase cables: up to 50-70 mm² (phase output single-phase PV inverter 8-15 kW)
- Three-phase cables: 1 phase of 4G10 to 4G25 mm² cable (PAC 15-20 kW power supply, VE 22 kW terminal)
- Copper bars: cross-section up to 15x5mm or 12x8mm (LV panel, compact connection)
⚠️ Difference TCA21 (Ø21mm) vs TCA22 (Ø22.5mm)
- TCA21 Ø21mm: cables ≤ 70 mm², bars ≤ 15x5mm → standard residential/tertiary installations ✅
- TCA22 Ø22.5mm: cables ≤ 95 mm², bars ≤ 20x5mm → high power installations (> 30 kW single, > 60 kW three)
6. Snap-on DIN rail mounting: rapid installation
TCA21s offer two mounting modes:
- Clip-on 35mm DIN rail: tool-free installation/removal in 5 seconds
- Screw mounting brackets: mounting on base plate or enclosure wall
7. Socomec French manufacturing: quality and reliability
Socomec, founded in 1922 and based in Benfeld (Alsace, France), is a European leader in low-voltage electrical equipment:
- 100% French manufacturing: ISO 9001 certified factory, rigorous quality control
- Recognised expertise: over 100 years' experience in electrical measurement
- Comprehensive range: current transformers from 5A to 5000A, all accuracy classes (0.2S to 3)
- Technical support: full documentation, assistance available
Installation and sizing
Sizing according to installation power
| Installation | Puissance | Courant max | TC Socomec recommandé |
|---|---|---|---|
| Onduleur PV mono | 12-15 kW | 52-65 A @ 230V | TCA21 100A/5A ou 150A/5A |
| Onduleur PV mono | 15-20 kW | 65-87 A @ 230V | TCA21 150A/5A ou 200A/5A ✅ |
| Onduleur PV mono haute puissance | 25-30 kW | 109-130 A @ 230V | TCA21 250A/5A ✅ ou TCA22 250A/5A |
| Onduleur PV triphasé (par phase) | 30-45 kW | 43-65 A @ 400V | TCA21 150A/5A ou 200A/5A ✅ |
| Onduleur PV triphasé (par phase) | 50-60 kW | 72-87 A @ 400V | TCA21 200A/5A ou 250A/5A ✅ |
| Borne recharge VE triphasé 22kW (par phase) | 22 kW | 32 A @ 400V | TCA21 50A/5A ou 100A/5A (marge élevée) |
| Pompe à chaleur 15-20 kW (par phase) | 15-20 kW | 22-29 A @ 400V | TCA21 50A/5A ou 100A/5A |
💡Sizing rule: choose CT with In ≥ 1.2 x rated installation current for safety margin and compliance with permanent overload 1.2 In.
Example: Three-phase inverter 50 kW → Current per phase = 50,000 / (√3 × 400) = 72A → Choose TCA21 200A/5A (200A ≥ 1.2 × 72A = 86.4A ✅)
Critical installation rules
| Règle | Prescription |
|---|---|
| Sens de passage primaire | Respecter le marquage L1/L2 (ou K/L) pour polarité correcte |
| Raccordement secondaire | S1/S2 (ou k/l) : S1 vers borne + appareil, S2 vers borne - ou neutre |
| Section câble secondaire | Min 1,5 mm² cuivre (recommandé 2,5 mm² si longueur > 10m) |
| Longueur max câble secondaire | ≤ 30-40m en 2,5 mm² pour Sn = 2,5VA (consulter abaques Socomec au-delà) |
| Court-circuit avant déconnexion | OBLIGATOIRE : utiliser doubles bornes pour court-circuiter S1-S2 avant retrait appareil |
| Mise à la terre | Relier borne PE du transformateur à la terre (si disponible) pour sécurité |
| Identification | Étiqueter clairement : "TC 200A/5A Phase L1" ou "TC 250A/5A Phase L2" selon circuit |
⚠️ Critical rule: never leave the secondary open
If the secondary is disconnected on load (open circuit), the CT behaves like a step-up transformer:
- Secondary overvoltage of up to several kV (danger of electrocution)
- Destructive heating of the magnetic core (saturation)
- Destruction of the transformer
✅ Solution: double short-circuit terminals
TCA21s have terminals enabling the secondary to be short-circuited before disconnection, eliminating any risk.
Checking and maintenance
- Initial visual check: check secondary terminals for tightness (torque 0.8 N.m recommended), absence of bore damage
- Secondary continuity test: measure S1-S2 resistance (typical 0.4-1.5 Ω depending on model), value > 10 Ω = internal disconnection
- Annual check: check terminal tightness, absence of abnormal heating, clean if dusty environment
- Periodic calibration: for tax/commercial metering, accuracy class check every 5-10 years (accredited laboratory)
Integration into the Wattuneed ecosystem
Socomec TCA21 transformers integrate perfectly with Wattuneed monitoring and energy management solutions:
- Photovoltaic production monitoring: precise measurement of output from 15-60 kW single-phase or three-phase inverters
- Metering of self-consumed energy: calculation of self-consumption rate, grid injection, etc.
- Energy management system (EMS ): real-time data to control loads (DHW tanks, EV terminals, batteries)
- Anomaly detection: monitoring of consumption drift, identification of malfunctions, etc.
- Tariff optimisation: monitoring of peak/off-peak consumption, red day shaving, etc.
- Reporting and compliance: reports for energy audits, certification (ISO 50001), etc.
In summary: your benefits with Socomec TCA21 CTs
- ✅ Accuracy class 0.5: highly accurate measurement ±0.5%, high performance commercial metering and PV monitoring
- ✅ Two ratings available: 200A/5A (20-45 kW) or 250A/5A (25-60 kW)
- ✅ 2 .5VA apparent power: compatible with DIRIS, COUNTIS power stations, compact installation
- ✅ FS 5 overcurrent factor: supports 1000-1250A peak without degradation
- ✅ Ø21mm bore: 50-70 mm² cables or 15x5mm copper bars
- ✅ S nap-on DIN rail mounting: quick installation without tools
- ✅ Enhanced safety: double short-circuit terminals, 3 kV insulation
- ✅ So comec French manufacturing: quality, durability, technical support
- ✅ IEC 61869-2 standards: commercial metering and billing compliance
Turn your photovoltaic installation into an intelligent production plant with the high-precision monitoring of Socomec TCA21 current transformers.
Wattuneed, your partner for measured and optimised photovoltaic installations.
Data sheet
- Type of electrical equipment
- Transformateur
Specific References
- UPC
- 768563818509
- EAN13
- 0768563818509
Socomec TCA21 Current Transformers - 200A/5A or 250A/5A - Class 0,5 - 2,5VA - Ø21mm — Electrical hardware
Socomec TCA21 Current Transformers - 200A/5A or 250A/5A - Class 0,5 - 2,5VA - Ø21mm by Mx Flex is available in our Electrical hardware catalog. Technical specifications: type of electrical equipment: Transformateur. Product weight: 0.6 kg. Reference: TCA21-200A-5A.