The BB1-63 series 10A 600V DC circuit breaker is a protection device specially designed for direct current photovoltaic installations. This miniature bipolar circuit-breaker (2P) provides essential triple protection: against overload, short-circuit and reverse current.



With its rated voltage of 600V DC and rated current of 10A, it is ideal for protecting small- to medium-power residential solar installations. Its 6 kA breaking capacity and thermomagnetic type B tripping curve guarantee reliable, reactive protection in the event of an electrical fault.



Designed to fit into DC solar cabinets, controllers and junction boxes, this compact circuit-breaker benefits from an optimised arc extinguishing system, crucial for DC safety. Its extended temperature range (-25°C to +70°C) means it can be used in a variety of environmental conditions.



Compliant with IEC 60947-2 / GB14048.2 standards, this circuit-breaker offers IP40 protection on all sides and accepts cable cross-sections from 2.5 to 25 mm². Ideal for securing your solar panel strings, protecting your inverters and guaranteeing the reliability of your photovoltaic installation.



Standard DIN rail mounting. Long mechanical life: 20,000 cycles. Sold individually.

DC 10A 600V circuit breaker - Photovoltaic protection BB1 Series

The BB1-63 series 10A 600V DC circuit breaker is an electrical protection device specially developed to meet the stringent requirements of DC photovoltaic installations. Unlike standard AC circuit breakers, this model incorporates specific technologies to safely manage the particularities of DC current generated by solar panels.






Triple protection for solar installations

This miniature two-pole circuit breaker provides three essential protection functions to guarantee the safety and reliability of your photovoltaic installation:

  • Overload protection: progressive thermal tripping when the current exceeds the rated value of 10A for any length of time, preventing excessive heating of cables and equipment.
  • Short-circuit protection: Instantaneous magnetic tripping (curve B) to quickly isolate a clear fault and limit material damage
  • Back-flow protection: Prevents unwanted back-flow of current, protecting solar panels and inverter from malfunctions






Electrical characteristics adapted to photovoltaics

The BB1-63 circuit-breaker has electrical characteristics specifically optimised for DC solar applications:

Caractéristique Valeur Signification
Tension nominale 600V DC Adapté aux systèmes jusqu'à 600V en courant continu
Courant nominal 10A Courant de fonctionnement permanent maximal
Courant maximal cadre 63A Capacité maximale de la série BB1-63
Pouvoir de coupure 6 kA Capacité à interrompre un courant de court-circuit
Courbe de déclenchement Type B Seuil 3-5 x In pour déclenchement magnétique
Type de déclencheur Thermomagétique Protection combinée thermique + magnétique
Tension d'impulsion 4 kV Résistance aux surtensions transitoires






Optimised arc extinguishing system

One of the major characteristics of direct current compared with alternating current is the difficulty of breaking an arc. Unlike alternating current, which naturally passes through zero 100 times per second (at 50 Hz), direct current maintains a stable arc that can persist and damage the circuit-breaker contacts.

The BB1-63 circuit-breaker incorporates an arc extinguishing system specifically designed for DC current, using an extinguishing chamber with metal grids that effectively split, cool and extinguish the arc when the contacts are opened. This scientific design guarantees safe, rapid disconnection, which is essential for protecting photovoltaic installations.

An effective arc extinguishing system is crucial to maintaining a safer solar system and extending the life of the DC circuit breaker.






Applications and fields of use

The DC 10A 600V circuit breaker can be used in a wide range of photovoltaic installation configurations:

  • DC solar cabinets: Protection of each string of panels before grouping
  • Photovoltaic junction boxes: Securing connections between panels and inverters
  • Charge controllers: Protection of charge controllers for stand-alone systems
  • Residential installations: Strings of 2 to 4 panels in series (depending on operating voltage)
  • Storage systems: Protection of DC links between batteries and hybrid inverters
  • Solar pumping: Securing DC circuits before conversion

To understand how to correctly integrate this circuit breaker into your installation, consult our detailed connection diagrams available on our website.






Sizing and choice of rating

The 10A rating is particularly suitable for the following installations:

Configuration Puissance approximative Exemple d'application
String 48V Jusqu'à 480W 1-2 panneaux 250W en série
String 120V Jusqu'à 1200W 3-4 panneaux 300-400W en série
String 240V Jusqu'à 2400W 6-8 panneaux 300-400W en série
String 400V Jusqu'à 4000W 10-12 panneaux 300-400W en série

To correctly size your protections and cables, use our voltage drop calculator available free of charge in the Wattuneed toolbox.






Durability and reliability

Designed for intensive use, the BB1-63 circuit-breaker offers excellent durability:

Type de cycle Valeur standard Valeur BB1-63
Cycles mécaniques (sans charge) 8500 cycles 20000 cycles
Cycles électriques (sous charge) 1500 cycles 4000 cycles

These values demonstrate the superior robustness of this circuit breaker compared with market standards, guaranteeing reliable long-term protection with minimum maintenance.






Installation and environment

The BB1-63 circuit-breaker is designed for easy integration into your existing electrical enclosures:

  • DIN rail mounting: fast, standard installation on 35 mm rail
  • Compact size: 2 DIN modules (36 mm wide)
  • Cable cross-section: Terminals accept 2.5 to 25 mm².
  • IP protection: IP40 on all sides, IP20 at terminals
  • Bipolar configuration: Simultaneous breaking of both poles (+ and -)

The circuit-breaker supports a wide operating temperature range (-25°C to +70°C), enabling it to be installed in a variety of environments, including outdoors in a suitable enclosure. The storage temperature ranges from -40°C to +85°C.






Compliance and standards

The BB1-63 circuit-breaker complies with current international standards for DC protection equipment:

  • IEC 60947-2: International standard for low-voltage circuit breakers
  • GB14048.2: Equivalent Chinese standard for circuit breakers
  • IEC 60068 resistance: Shock (2.6) and impact (2.27) tests validated.

These certifications guarantee the quality, reliability and safety of the product for use in professional electrical installations.






Complementary to your photovoltaic system

For complete protection of your solar array, the DC circuit-breaker should be used in conjunction with other safety devices:

  • DC Type 2 lightning arrester: Protection against atmospheric overvoltages
  • DC disconnector: Manual disconnection for safe maintenance
  • Protection box: Protection grouped together in a watertight enclosure
  • DC fuses: Additional protection for certain configurations

Discover our complete range of DC protection enclosures and photovoltaic surge protectors to provide effective protection for your installation.






Advantages of the BB1-63 circuit breaker

  • Specific direct current: Designed for the constraints of photovoltaic DC
  • Triple protection: Overload + short-circuit + backflow protection
  • Optimised arc extinguishing: Specific system for safe DC breaking
  • High voltage: Up to 600V DC for modern systems
  • Compact size: 2 DIN modules to save space
  • Superior durability: 20,000 mechanical cycles, 4,000 electrical cycles
  • Wide temperature range: -25°C to +70°C for all environments
  • Compliant with standards: IEC 60947-2 / GB14048.2
  • Easy installation: standard DIN rail mounting
  • Type B curve: suitable for photovoltaic loads






Installation recommendations

To ensure the correct operation and long life of your DC circuit breaker :

  • Install the circuit breaker in a weatherproof enclosure adapted to outdoor conditions if necessary
  • Use the recommended cable cross-sections (2.5 to 25 mm²) to avoid overheating.
  • Check that the voltage of your string never exceeds 600V DC open circuit
  • Ensure that the short-circuit current of your installation does not exceed 6 kA
  • Leave sufficient ventilation space around the circuit-breaker
  • Observe the correct polarity when connecting (+ and -)
  • Perform a function test after installation






Packaging and reference

The DC 10A 600V circuit breaker is sold individually, ready to be installed on a standard DIN rail in your photovoltaic protection cabinet.

If you have any technical questions about sizing your DC protection, compatibility with your solar installation, or advice on choosing the right rating, our support team is at your disposal at support.wattuneed.com.