Parafoudre AC Citel - Type 2 - 2P - 40kA - 230/400V - Réf. DS240S-230
DON'T LET LIGHTNING DESTROY YOUR PHOTOVOLTAIC INSTALLATION
The Citel DS240S-230 Type 2 2P 40kA surge protector is your shield against power surges. Made in France, it protects your inverters, batteries and sensitive electronic equipment with formidable efficiency: protection level Up ≤ 1.5 kV, response time < 25 nanoseconds. Complies with NF EN 61643-11 and NF C 15-100.
- High-performance type 2: 40kA Imax, indirect lightning protection and mains overvoltage protection
- 2P configuration: single-phase (L-N) or two-phase (L1-L2) 230/400V
- Maximum safety: thermal disconnector + green/red indicator light
- Citel French manufacturing: 35 years of expertise, NF certification
Citel DS240S-230 Type 2 2P 40kA AC Surge Protector - Protection for photovoltaic installations
The Citel DS240S-230 modular surge protector is an essential protection device for securing your photovoltaic installations and AC electrical networks against atmospheric surges (lightning) and switching surges (electrical network). Designed and manufactured in France by Citel, the European leader in lightning protection, this Type 2 class II arrester offers high-performance protection with a maximum discharge current (Imax) of 40kA per phase.
Why install a lightning arrester on your photovoltaic installation?
Photovoltaic installations are particularly exposed to the risk of power surges:
- Exposure to height: rooftop solar panels = risk of direct or indirect lightning strike
- Long cable lines: between panels, inverter and switchboard = antennae that pick up surges
- Sensitive electronics: inverters, batteries, monitoring systems = very vulnerable to voltage peaks
- Cost of equipment: inverter 2000-5000€, batteries 5000-15000€ = investment that absolutely must be protected
💡 Normative obligation: According to standard NF C 15-100 (section 443) and the Belgian RGIE (article 4.4.4), the installation of lightning arresters is mandatory in certain cases:
- Buildings equipped with lightning conductors
- Overhead power supplies in lightning risk zones (AQ2, AQ3, AQ4)
- Structures open to the public
- Photovoltaic installations (recommended by guide UTE C 15-712-1)
Typical applications for the Citel DS240S-230 lightning arrester
- Residential and tertiary photovoltaic installations: protection on the AC side between inverter and main switchboard
- AC protection cabinets: integration in single-phase or three-phase cabinets
- Distribution boards: protection at the head of the main or sub-distribution board
- Heat pumps: protection for exposed outdoor equipment
- EV charging stations: securing outdoor wallboxes
- Commercial buildings: protection of sensitive electrical networks
Technical specifications
| Paramètre | Valeur |
|---|---|
| Fabricant | Citel (Groupe Servalec) |
| Référence fabricant | DS240S-230 |
| EAN-13 | 0712971139411 |
| Gamme | DS2 (Déconnecteur Série 2) |
| Type de parafoudre | Type 2 / Classe II (protection intermédiaire) |
| Configuration | 2P (bipolaire : L-N ou L1-L2) |
| Technologie | Varistances à oxyde métallique (MOV) |
| Courant de décharge maximal (Imax) | 40 kA (8/20 µs) par pôle |
| Courant de décharge nominal (In) | 20 kA (8/20 µs) par pôle |
| Niveau de protection (Up) | ≤ 1,5 kV (L-N) / ≤ 2,5 kV (L-PE, N-PE) |
| Tension maximale de service continue (Uc) | 255 V AC (L-N) / 440 V AC (L-L) |
| Tension assignée | 230 V AC monophasé / 400 V AC biphasé |
| Fréquence | 50/60 Hz |
| Courant de fuite (à Uc) | < 1 mA |
| Temps de réponse | < 25 ns (nanoseconde) |
| Déconnecteur thermique intégré | Oui (déconnexion automatique en fin de vie) |
| Indicateur visuel d'état | Voyant vert = actif / Voyant rouge = défaut/fin de vie |
| Contact auxiliaire | 1 contact sec inverseur (NO/NC) pour signalisation à distance (optionnel selon modèle) |
| Section de raccordement | Rigide : 1,5 à 25 mm² / Souple : 1,5 à 16 mm² |
| Couple de serrage | 2,5 N.m |
| Montage | Rail DIN 35 mm |
| Largeur (modules 9mm) | 2 modules (18 mm) |
| Dimensions (H x L x P) | 85 mm x 18 mm x 65 mm |
| Poids | 0,120 kg |
| Degré de protection IP | IP20 (face avant) |
| Classe de protection | Classe I (mise à la terre obligatoire) |
| Température de fonctionnement | -40°C à +85°C |
| Humidité relative | 0 à 95% (sans condensation) |
| Altitude max | 4000 m |
| Normes | NF EN 61643-11 (IEC 61643-11), NF C 15-100 |
| Certifications | CE, NF, marque Citel (qualité française) |
| Durée de vie | Jusqu'à 20 ans (selon exposition et entretien) |
| Pays de fabrication | France 🇫🇷 |
Why choose the Citel DS240S-230 surge protector?
1. Type 2: high-performance intermediate protection
The Type 2 surge protector (formerly Class II) is the mandatory level of protection at the head of the switchboard according to NF C 15-100. It protects against :
- ✅ Indirect lightning strikes: surges induced by lightning falling nearby (radius 500m-1km)
- ✅ Manoeuvring overvoltages: mains switching, external short-circuit, sudden load variations
- ✅ Propagated overvoltages: surges rising from the distribution network
2. 40kA discharge capacity: safe sizing
With an Imax of 40kA (8/20µs) and an In of 20kA, this arrester offers:
- Comfortable safety margin: capable of absorbing significant overvoltages without degradation
- Extended service life: withstands several successive events before replacement
- Standards compliance: exceeds minimum NF C 15-100 requirements (In ≥ 5kA for Type 2)
3. 2P configuration: single-phase and two-phase versatility
The 2-pole model protects :
- Single-phase installations: protection L-N (phase-neutral) + PE earthing
- 400V two-phase installations: L1-L2 protection (2 phases) + PE earthing
- Specific circuits: protection of a dedicated circuit (e.g. PV inverter, VE terminal)
⚠️ Important note: For three-phase installations (3P+N), use the Citel DS240S-400 4-pole model (3P+N).
4. Integrated thermal disconnector: maximum safety
In the event of varistor ageing or failure, the automatic thermal disconnector:
- ✅ Isolates the faulty arrester: avoids any risk of overheating or fire
- ✅ Maintains continuity of service: the installation remains powered (but unprotected → immediate replacement required)
- ✅ Visual signalling: red LED + dry contact option for remote alarm.
5. Protection level Up ≤ 1.5 kV: electronic safety
The protection level (Up) represents the maximum residual voltage allowed to pass through the arrester. With Up ≤ 1.5 kV:
- ✅ Effective protection of PV inverters: typical withstand range 2-4 kV → comfortable safety margin.
- ✅ Lithium battery safety: BMS (Battery Management System) protected against voltage peaks.
- ✅ S ensitive electronic equipment: monitoring systems, smart meters, home automation boxes
6. Response time < 25 ns: ultra-fast protection
MOV varistor technology enables a response in less than 25 nanoseconds:
- Instant interception: the surge is clipped before it reaches sensitive equipment
- Complete protection: no time window for exposure
7. Citel French manufacturing: quality and expertise
Citel (Servalec group) has been the French leader in lightning protection since 1986:
- French manufacturing: design, production and quality control in France
- Recognised expertise: over 35 years' experience in lightning protection
- NF certifications: compliance with the most demanding French standards
- Technical support: full documentation, technical assistance available
Installation and sizing
Installation rules in accordance with NF C 15-100
| Règle | Prescription |
|---|---|
| Emplacement | En tête de tableau, après disjoncteur général ou disjoncteur d'abonné |
| Protection amont | Disjoncteur ou fusible : 32-63A courbe C (selon puissance installation) |
| Câblage | Câbles courts et droits : longueur totale L ≤ 0,5 m (aller + retour) |
| Section conducteurs | L/N : 6-10 mm² cuivre / PE : 6-16 mm² cuivre (min 6 mm²) |
| Mise à la terre | Connexion PE obligatoire, résistance terre ≤ 30 Ω (idéal ≤ 10 Ω) |
| Cascade Type 1 + Type 2 | Si parafoudre Type 1 en amont : distance ≥ 10m ou découplage inductif |
| Signalisation | Voyant visible + étiquette identification claire |
⚠️ Crucial rule: wiring length
The total length of conductors between the arrester and the connection point must be ≤ 0.5 metres (outward + return). Why must this be the case?
- Each metre of cable adds ~1 µH of inductance
- Inductance = rise in residual voltage during rapid discharge (high dU/dt)
- Cable too long = degraded level of protection (Up increases)
💡 Tip: prefer "V" or "T" connections rather than straight lines to minimise lengths.
Sizing according to type of installation
| Installation | Parafoudre AC recommandé | Parafoudre DC (côté PV) |
|---|---|---|
| PV résidentiel 3-6 kW mono | Citel DS240S-230 (2P 40kA) ✅ | Parafoudre DC Type 2 (si câbles longs) |
| PV résidentiel 8-12 kW mono | Citel DS240S-230 (2P 40kA) ✅ | Parafoudre DC Type 2 recommandé |
| PV résidentiel 10-20 kW tri | Citel DS240S-400 (4P 40kA 3P+N) | Parafoudre DC Type 2 obligatoire |
| Borne de recharge VE mono | Citel DS240S-230 (2P 40kA) ✅ | N/A |
| Pompe à chaleur mono/tri | Selon configuration (2P ou 4P) | N/A |
Checking and maintenance
- Monthly visual check: green light on (lightning arrester operational)
- Annual test: check PE continuity, tighten terminals (torque 2.5 N.m)
- After a violent storm: visual check + electrical test (measure insulation resistance)
- Immediate replacement if: red light, disconnector tripped, traces of overheating
📅 Lifespan: A well-installed lightning arrester that is subjected to little stress can last 15-20 years. In areas with high thunderstorm activity (>25 days/year), lifespan is reduced to 8-12 years.
Integration into the Wattuneed ecosystem
The Citel DS240S-230 surge protector integrates perfectly into Wattuneed's photovoltaic and protection solutions:
- Wattuneed AC protection cabinets: pre-equipped installation with integrated surge arrester
- Solar inverters: essential protection for Deye, Huawei, Solis, Growatt inverters, etc.
- Storage batteries: securing BMS and management electronics (Pylontech, BYD, Dyness)
- Monitoring systems: protection of communication modules (Wi-Fi, 4G, Ethernet).
🎯 In summary: your advantages with the Citel DS240S-230 surge protector
- ✅ High-performance protection: Type 2, 40kA Imax, Up ≤ 1.5 kV
- ✅ 2 P configuration: single-phase (L-N) or two-phase (L1-L2) 230/400V
- ✅ Maximum safety: thermal disconnector + visual signalling
- ✅ Ultra-fast response: < 25 ns, instant protection
- ✅ Citel French manufacturing: quality, expertise, NF certifications
- ✅ S tandards compliance: NF EN 61643-11, NF C 15-100, RGIE
- ✅ Durability: 15-20 year service life, manufacturer's warranty
- ✅ S imple installation: 35mm DIN rail, 2 modules (18mm), quick wiring
Don't let lightning destroy your photovoltaic investment. Protect your inverters, batteries and electronic equipment with the Citel DS240S-230 lightning arrester, the French benchmark for lightning protection. ⚡🛡️
Wattuneed, your partner for secure, long-lasting photovoltaic installations. 🌞⚡