250A protective box for Delong battery
250A protective box for Delong battery
250A protective box for Delong battery

250A Bipolar DC Protection Box for Delong Lithium Batteries

Dhs4,716.82
Tax included
Coffret-protection-250A-Delong
0768563823817

The DC 250A bipolar protection box is the central safety component for your energy storage systems. Designed specifically for Delong batteries (48V / 100Ah and above), this box ensures total isolation by simultaneously disconnecting the positive (+) and negative (-) poles.

The major advantage of this bipolar protection is its ability to completely isolate the circuit: unlike conventional protection, it ensures that no residual current flows during shutdown, thus protecting the user and the inverter from electric arcs and insulation faults. This device is essential for preserving the life of your lithium cells in the event of overloads.

Equipped with a robust 250A circuit breaker, it can withstand current peaks without overheating. Its omnipolar manual cut-off allows you to work on the installation with complete peace of mind.

Technical advantages:

  • Bipolar safety: Simultaneous cut-off of (+) and (-) for true galvanic isolation.
  • 250A rating: Ideal for high-power discharges from lithium battery banks.
  • Full protection: Thermal and magnetic tripping on both poles.
  • Robust design: IP65 waterproof enclosure suitable for demanding environments.
  • Ready to use: Internal terminal blocks for large cross-section cables (up to 95mm²).
ℹ️ Cette liste est non exhaustive. Contactez-nous pour vérifier une combinaison.

250A Bipolar DC Protection Box for Delong Batteries – Ready to Install


The 250A protection box for Delong batteries is a turnkey solution for securing your energy storage installations. This box provides complete bipolar protection, simultaneously isolating the positive and negative poles to ensure maximum safety against overloads and short circuits.






Box contents

This box is delivered complete, pre-wired and ready to install:

  • IP65 box: Robust box offering total protection against dust and water splashes.
  • 2P 250A DC1000V bipolar circuit breaker (TOMZN - TOM7Z): The central safety device allowing simultaneous disconnection of both polarities.
  • Two 1 m 95 mm² cables with terminals: High-performance connection for connecting your Delong battery packs to the box.
  • 4 x 50 mm² cables, 1.50 m long, with terminals: Secure, optimised connection to the inverter.






How the box works

The box is designed to centralise and protect the direct current reliably:

  • Delong batteries are connected to the box via 95 mm² cables.
  • Bipolar protection: The 2P 250A circuit breaker acts on both lines (+ and -), ensuring that no residual current flows in the event of a power cut.
  • The four 50 mm² cables then distribute the power stably to the inverter.

Safety principle: By cutting both poles simultaneously, this bipolar cabinet provides true galvanic isolation, protecting the user and the inverter's electronics from any insulation faults.






Typical applications

  • Residential or professional installations equipped with Delong lithium batteries.
  • Modular storage systems mounted in parallel requiring safe isolation.
  • Bipolar protection essential for hybrid PV installations and isolated sites.






Advantages of the box

  • Bipolar safety: Simultaneous isolation of (+) and (-) for increased protection.
  • Turnkey solution: Box, high-section cabling and circuit breaker included.
  • Quick installation: Internal terminal blocks and cables pre-fitted with terminals.
  • DC compliance: Equipment specifically calibrated for high-intensity direct currents (250A).
  • Safe maintenance: Allows the battery bank to be completely isolated during maintenance work.






Commissioning

  1. Check that the bipolar circuit breaker is in the OFF position.
  2. Connect the 95 mm² cables to the Delong battery terminals.
  3. Connect the 50 mm² cables to the DC inputs of the inverter.
  4. It is essential to observe the polarity (+ red, - black) on both poles of the circuit breaker.
  5. Set the circuit breaker to the ON position to power up the installation.






Safety and maintenance

  • 2P 250A circuit breaker: Resettable magnetic and thermal protection on both poles.
  • Optimised cabling: 95 mm² and 50 mm² cross-sections to minimise voltage drops and heating.
  • IP65 rating: Suitable for technical environments (battery rooms, garages).
  • Maintenance: Periodic checking of terminal tightness and testing of the circuit breaker release button.






FAQ - 250A protection box for Delong battery

1. Why is this protection box described as "bipolar"? +
It is called bipolar because it simultaneously cuts off the positive and negative poles. In direct current (DC), this double cut-off is an essential safety feature to completely isolate the lithium battery from the inverter, thus preventing any risk of electric arc or return current during maintenance.
2. Is it compatible with the entire Delong battery range? +
This box is ideally designed for Delong 48V/51.2V models of 100Ah and above. Thanks to its 250A capacity, it can handle the high discharge powers required by modern hybrid inverters without overheating, thus ensuring the longevity of your photovoltaic installation.
3. Why does the box use different cable cross-sections? +
The 95 mm² input ensures an ultra-robust connection from the battery bank to minimise voltage drops. The 50 mm² outputs are designed to support 250A while remaining compatible with the standard terminal blocks of most inverters on the market.
4. Can I install this equipment myself? +
Although the box is delivered ready to use, handling high-intensity lithium systems (250A) requires technical expertise to ensure that the terminals are correctly tightened and the connections are watertight. We strongly recommend that a qualified technician be called in to validate the compliance of the installation.
Coffret-protection-250A-Delong

Data sheet

Type of electrical equipment
Protection box

Specific References

UPC
768563823817
EAN13
0768563823817
MPN
Coffret-protection-250A-Delong

You might also like

Loading...