Schneider Breaker mono 40A

Disjoncteur Schneider Resi9 - 2P - 50A - Courbe C - 400V - R9F64250

€58.70
Tax included
A9F64250
0712971137578

Secure your electrical installations effectively with the Schneider IC60A modular circuit breaker - 2-pole, 50 A, curve C, 400 V.
Designed to protect your circuits against overloads and short circuits, it guarantees maximum safety for your house, flat, garage, workshop or annex.
Easy to install in a standard switchboard, it supports high loads such as heating, water heaters, hand-held power tools and circuits used for teleworking.
Durable, reliable and compliant with European standards, it ensures optimum energy continuity even during intensive use.
Choose high-performance residential protection and secure your home today.

Comments (0)

No customer reviews for the moment.

Circuit breaker Schneider Electric Resi9 2P 50A Courbe C 400V - Reliable residential electrical panel protection



Safety and reliability for your electrical installation

The Schneider IC60A circuit breaker - 2 poles, 50 A, curve C - is an essential component for any modern residential installation. Designed to protect your electrical circuits against overloads and short circuits, it fits easily into a standard DIN panel. Its modular, robust design meets European standards, guaranteeing a high level of safety for your house, flat, garage or annexe.

Reliable and durable, this circuit breaker is ideal for residential environments in Northern Europe - where electricity needs may be supported by heaters, pumps, domestic appliances or workshop tools.






Benefits and protection

  • Overload and short-circuit protection: this circuit-breaker trips instantly in the event of an anomaly, preventing any risk of fire or damage to equipment.
  • 50 A capacity - suitable for powerful circuits: perfect for dedicated circuits (workshop, DIY workshop, garden workshop, local heating, cumulus, etc.).
  • Curve C - good compromise for variable and reactive loads: protects circuits with motorised appliances or household equipment without tripping on start-up.
  • Quick and easy installation: standard DIN rail mounting, simple connection without specialist tools, ideal for commissioning or panel upgrades.
  • Adapted to North European residential requirements: stable in the face of voltage variations and the constraints of intensive use, even in winter or during consumption peaks.






Residential uses - concrete scenarios

  • Standard house or flat: protection of a heating circuit, a water heater, a socket circuit or a radiator circuit - ideal for Belgium, where heating requirements are high in winter.
  • Garage or DIY workshop: power supply for power tools, drill, compressor or woodworking machine - curve C and 50 A rating provide reliable protection without false alarms.
  • Annex, shed or storeroom: independent circuits for freezer, pump, lighting, with no risk of overload.
  • Teleworking or home office: dedicated circuits for computers, printers, boilers or pumps - safety and reliability for a stable, long-lasting installation.
  • Extension or renovation: upgrade an existing switchboard to accommodate a higher load or additional circuits, without compromising safety.






Focus on reliability and compatibility

  • Compliance with European standards: designed to EN/IEC standards to guarantee safety, performance and longevity.
  • Standard switchboard compatibility: can be integrated without modification into standard domestic enclosures in Belgium and Europe.
  • Robust, durable materials: strong enclosure, high-quality internal components, withstands numerous open/close cycles without wear and tear.
  • Minimal maintenance: no periodic servicing required, making it a reliable, long-lasting solution for everyday use.

Features

Main
range Resi9
Product name Resi9 MCB
Type of product or component Miniature circuit breaker
Device application Distribution
Description of poles 2P
Number of protected poles 2
[In] rated operating current 20 A at 30 °C
Mains type AC
In] rated operating current 50 A
Release technology Thermal-magnetic
Tripping curve C
breaking capacity 10 kA Icu at 220...240 V a.c. 50/60 Hz according to EN/IEC 60947-2
6 kA Icu at 380...415 V a.c. 50/60 Hz according to EN/IEC 60947-2
4500 A Icn at 400 V a.c. 50/60 Hz according to EN/IEC 60898-1
Breaking capacity 3000 A Icn at 230 V a.c. 50/60 Hz according to EN/IEC 60898-1
category of use Category A in accordance with EN/IEC 60947-2
disconnectability Yes in accordance with EN/IEC 60898-1
Yes in accordance with EN/IEC 60947-2
standards EN/IEC 60947-2
EN/IEC 60898-1
Mains frequency 50/60 Hz
tripping limit
magnetic
8 x In +/- 20 % [Ics
[Ics] rated breaking capacity
short-circuit service
10 kA 100 % according to EN/IEC 60947-2 - 220...240 V a.c. 50/60 Hz
6 kA 100 % according to EN/IEC 60947-2 - 380...415 V a.c. 50/60 Hz
limitation class 3 according to EN/IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz in accordance with EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV according to EN/IEC 60947-2
fully apparent breaking Yes
control type type of control
local signalling trip indicator
installation mode installation mode
mounting bracket mounting bracket
9 mm pitch 4
connection method Single terminal (top or bottom) 1...35 mm² rigid
Single terminal (top or bottom) 1...25 mm² flexible
wire stripping length 14 mm for top or bottom connection
tightening torque 3.5 N.m top or bottom