2

    copy of Ultracel GEL battery 12V 100Ah

    €138.94
    Tax included
    0561
    0712971127623

    Ultracel GEL battery 12V 100Ah.

    Cycle Applications : 1200 to 50% discharge.

    Dimensions (mm) : 342 x 185 x 270

    Weight (Kg) : 31

     

     

    100% secure payments

    copy of Ultracel GEL...

    €138.94

    Background battery AGM Ultracell 100ah 

    " Ultracel GEL  battery 12V 100Ah "

    Gel 100Ah

     

    Gel batteries are sealed batteries: no maintenance, no addition of distilled water. Strengthened compared to flooded batteries. Safety
    A gel battery to withstand the discharge to 560% and its rated capacity when discharged holding time is short. This series has a longer discharge time compared to other batteries. The special plate design increases the life of the battery and especially in warmer temperatures. A separator in the battery improves performance. It also has a longer
    retention time.

    • Rated voltage: 12V 
    • Capacity: 100Ah
    • Dimensions : 342 x 185 x 270 mm
    • Weight: 31 Kg

     

    Cycle life compared to the depth of discharge

     

    cycle vie battery Ultracell 100Ah

     

    0561
    5 Items

    Data sheet

    Voltage
    12V
    Technology
    Gel
    Battery capacity
    65Ah
    Terminal type - Standard terminal
    F10
    Terminal type - Optional terminal
    F6
    Rated capacity
    41.6 AH/41.6A - (1hr, 1.60V/cell, 25°C / 77°F)
    48.9 AH/16.3A - (3hr, 1.75V/cell, 25°C / 77°F)
    56.0 AH/11.2A - (5hr, 1.75V/cell, 25°C / 77°F)
    62.5 AH/6.50A - (10hr, 1.80V/cell, 25°C / 77°F)
    65.0 AH/3.38A - (20hr, 1.80V/cell, 25°C / 77°F)
    Maximum discharge current
    780A (5s)
    Internal resistance
    Approx 7.3mΩ
    Operating temperature Temperature range
    Discharge: -15 ~ 50°C (5 ~ 122°F)
    Load: 0 ~ 40°C (5 ~ 104°F)
    Storage: -15 ~ 40°C (5 ~ 104°F)
    Nominal operating temperatures
    25 ± 3°C (77 ± 5°F)
    Cycle of use
    Initial charge current less than 19.5A Voltage 14.4V ~ 15.0V at 25°C (77°F) Temperature coefficient -30mV/°C
    Standby use
    No limit to initial charge current Voltage 13.5V ~ 13.8V at 25°C (77°F) Temperature coefficient Coefficient -20mV/°C
    Nominal service life at 20°C
    10 years
    Self-discharge
    Ultracell batteries can be stored for up to 6 months at 25°C (°77F), after which a new charge is required. For higher temperatures, the time interval will be shorter.
    Weight
    31 kg
    Video Youtube 1 - ID
    mfq0AScBnfU

    Specific References

    UPC
    712971127623
    EAN13
    0712971127623
    New

    Download

    FicheT UltracellUL65-12-FR

    Download (377.35KB)