EP30 disjoncteur 3kA 3P C 40A

Disjoncteur Schneider Resi9 XE - 2P - 50A - Courbe C - 3kA - 230/400V - Réf. R9EFC250

€50.60
Tax included
ABBVY32C50
0768563816864

PROTECT YOUR HIGH-POWER CIRCUITS UP TO 11.5 kW



The Schneider Resi9 XE 2P 50A curve C 3kA circuit breaker is THE partner for demanding photovoltaic installers and electricians. Secure your solar inverters up to 12 kW, 11 kW VE charging stations, heat pumps and high-power heating circuits with legendary Schneider Electric reliability.



  • 2P two-pole 50A: simultaneous phase + neutral breaking (or 2 phases 400V)
  • Versatile C-curve: PV inverters, EV terminals, heat pumps, heating systems
  • 3kA breaking capacity: suitable for standard residential and commercial applications
  • 35mm DIN rail: quick installation (4 modules / 36mm)



Ideal for 10-12 kW photovoltaic installations

Circuit breaker Schneider Resi9 XE 2P 50A curve C 3kA - High-power residential protection



The Schneider Electric Resi9 XE 2P 50A C-curve modular circuit breaker is designed to effectively protect high-power residential and commercial electrical circuits against overloads and short circuits. With its breaking capacity of 3kA and its C trip curve, it is the ideal solution for protecting your installations up to 50A in bipolar configuration (phase + neutral or 2 phases).






Typical applications

  • Photovoltaic installations: AC protection of single-phase solar inverters up to 12 kW (inverter output circuit to main switchboard)
  • Electric vehicle charging points: charging circuits up to 11 kW single-phase (wallbox)
  • Residential heat pumps: protection of air/water heat pumps up to 10 kW electric
  • High-power electric heating: convectors, inertia radiators, underfloor heating (circuits up to 11.5 kW @ 230V)
  • Electric hot water cylinders: 200-300 litre water heaters with steatite or armoured resistance
  • Professional kitchen equipment: ovens, hobs, professional coffee machines
  • Residential air conditioning: high-power centralised air conditioning units






Technical specifications



Parameter Value
Range Resi9 XE
Product name Resi9 XE MCB (Miniature Circuit Breaker)
Manufacturer reference R9EFC250
EAN-13 0768563816864
Product type Miniature modular circuit breaker
Application Residential and commercial distribution
Pole configuration 2P (double pole)
Protected poles 2 protected poles
Rated operating current (In) 50 A at 30°C
Mains type AC (alternating current)
Tripping technology Thermal-magnetic
Tripping curve C
Breaking capacity (Icn) 3000 A at 230/400 V AC 50/60 Hz (EN/IEC 60898-1)
Service breaking capacity (Ics) 3000 A (100% Icn)
Limiting class 3
Magnetic tripping limit 5 to 10 x In (250-500A for 50A)
Rated operating voltage (Ue) 230 V AC single-phase / 400 V AC two-phase 50/60 Hz
Rated insulation voltage (Ui) 440 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp) 4 kV
Frequency 50/60 Hz
Type of control Toggle switch
Local indication Mechanical ON/OFF indication
Mounting Clip-on 35mm DIN rail
Module (9mm wide) 4 modules (36 mm)
Dimensions (H x W x D) 85 mm x 36 mm x 75 mm
Weight 0.240 kg (approx.)
Colour White (front)
Mechanical life 20,000 cycles
Electrical life 10,000 cycles
Connection mode Tunnel terminals (top/bottom)
Terminal capacity Flexible ≤16 mm² / Rigid ≤25 mm²
Tightening torque 2 N.m
Degree of protection IP IP20 (IEC 60529) / IP40 (modular enclosure)
Pollution level 2
Overvoltage category III
Operating temperature range -20°C to +60°C (derating above 30°C)
Storage temperature -40°C to +80°C
Standards EN/IEC 60898-1
Certifications CE, CEBEC






Why choose the Schneider Resi9 XE 2P 50A curve C circuit breaker?



1. C curve: the perfect balance for mixed installations

The C tripping curve offers a magnetic threshold of 5 to 10 times the rated current (i.e. 250-500A for a 50A). This characteristic guarantees:

  • Effective protection against short-circuits: instantaneous tripping from 250A
  • Inrush current tolerance: avoids nuisance tripping when starting heat pumps, compressors, transformers, etc.
  • Versatility: suitable for resistive loads (heating), inductive loads (motors) and capacitive loads (photovoltaic inverters).



2. 2P configuration: secure bipolar breaking

The protected 2-pole circuit-breaker provides :

  • Simultaneous phase + neutral breaking (single-phase): enhanced safety for maintenance, complete isolation of the circuit
  • 2-phase breaking (two-phase 400V): protection of two-phase loads (certain heat pumps, industrial machines)
  • Standards compliance: meets Belgian and European requirements (RGIE, NF C 15-100)



3. 3kA breaking capacity: suitable for residential/tertiary use

The 3000A (3kA) breaking capacity is perfectly sized for :

  • ✅ S tandard residential installations: typical short-circuit current 1.5-2.5kA at end of line
  • Branch circuits downstream of the main switchboard: protection of sub-divisional switchboards
  • Domestic photovoltaic installations: AC inverter protection 3-12kW

💡 Good to know: For installations with high short-circuit currents (close to transformers, large subscriptions), give preference to the iC60N (6kA) or iC60H (10kA) ranges.



4. 50A capacity: high-power circuits

With 50A @ 230V = 11.5 kW of protected power, this circuit-breaker protects :

  • 🔋 Photovoltaic inverters up to 12 kW AC (e.g. Deye SUN-12K-SG04LP3, Huawei SUN2000-12KTL-M2)
  • ⚡ 1 1 kW single-phase EV charging stations (Type 2 accelerated charging)
  • 🌡️ Heat pumps 8-10 kW electric (thermal output 25-35 kW)
  • 🔥 High-power central heating (electric radiators, underfloor heating)






🔧 Installation and sizing



Sizing rules

Puissance charge (230V) Courant nominal Disjoncteur recommandé Section câble mini (cuivre)
9,2 kW 40 A Disjoncteur 40A courbe C 10 mm²
11,5 kW 50 A Disjoncteur 50A courbe C 10 mm²
14,5 kW 63 A Disjoncteur 63A courbe C 16 mm²



⚠️ Warning: Always check cable cross-section, line length and voltage drop. For precise calculations, use our cable section calculator.



Installation advice

  • DIN rail mounting: clip the circuit breaker onto a standard 35mm DIN rail, 4 modules wide (36mm).
  • Wiring: use rigid conductors (H07V-R/U) or flexible conductors with ferrules (H07V-K + crimp ferrules)
  • Minimum cross-section: 10 mm² copper for 50A (depending on length and installation method, consult RGIE/NF C 15-100)
  • Tightening torque: 2 N.m (check with a torque screwdriver)
  • Identification: clearly label the protected circuit (e.g. "PV Inverter", "VE Wallbox", "PAC")
  • Ventilation: allow 10-15mm spacing above/below for heat dissipation






🌞 Focus: Integration in photovoltaic installations

The Resi9 XE 2P 50A circuit breaker is perfectly suited to AC protection of single-phase solar inverters:



Sizing for PV inverters (examples).

Onduleur Puissance AC Courant max (230V) Disjoncteur recommandé
Deye SUN-8K-SG04LP3 8 kW 34,8 A 40A courbe C
Deye SUN-10K-SG04LP3 10 kW 43,5 A 50A courbe C ✅
Huawei SUN2000-12KTL-M2 12 kW 52,2 A 63A courbe C
Solis S6-GR1P10K 10 kW 43,5 A 50A courbe C ✅



💡 General rule: choose a circuit breaker with rating ≥ 1.25 x rated inverter current (normative safety margin).




In summary: your advantages with the Resi9 XE 2P 50A

  • ✅ S chneider Electric quality: proven reliability, 20,000 mechanical operations guaranteed
  • ✅ 2 P 50A configuration: high-power circuits up to 11.5 kW @ 230V
  • Versatile C-curve: resistive, inductive and capacitive loads
  • 3kA breaking capacity: suitable for standard residential and tertiary applications
  • DIN rail mounting: fast, modular installation (4 modules / 36mm)
  • European standards: EN/IEC 60898-1 compliance, CEBEC certification
  • Multiple applications: photovoltaics, EV terminals, heat pumps, heating



Wattuneed, your partner for secure, high-performance electrical and photovoltaic installations.

ABBVY32C50

Data sheet

Type of electrical equipment
Disjoncteur

Specific References

UPC
768563816864
EAN13
0768563816864