AC 2P 40 surge arrester
AC 2P 40 surge arrester
AC 2P 40 surge arrester
AC 2P 40 surge arrester
AC 2P 40 surge arrester

Parafoudre AC Citel - Type 2 - 2P - 40kA - 230/400V - Réf. DS240S-230

€20.78
Tax included
DS240S-230
0712971139411

DON'T LET LIGHTNING DESTROY YOUR PHOTOVOLTAIC INSTALLATION



The Citel DS240S-230 Type 2 2P 40kA surge protector is your shield against power surges. Made in France, it protects your inverters, batteries and sensitive electronic equipment with formidable efficiency: protection level Up ≤ 1.5 kV, response time < 25 nanoseconds. Complies with NF EN 61643-11 and NF C 15-100.



  • High-performance type 2: 40kA Imax, indirect lightning protection and mains overvoltage protection
  • 2P configuration: single-phase (L-N) or two-phase (L1-L2) 230/400V
  • Maximum safety: thermal disconnector + green/red indicator light
  • Citel French manufacturing: 35 years of expertise, NF certification

Citel DS240S-230 Type 2 2P 40kA AC Surge Protector - Protection for photovoltaic installations



The Citel DS240S-230 modular surge protector is an essential protection device for securing your photovoltaic installations and AC electrical networks against atmospheric surges (lightning) and switching surges (electrical network). Designed and manufactured in France by Citel, the European leader in lightning protection, this Type 2 class II arrester offers high-performance protection with a maximum discharge current (Imax) of 40kA per phase.






Why install a lightning arrester on your photovoltaic installation?

Photovoltaic installations are particularly exposed to the risk of power surges:

  • Exposure to height: rooftop solar panels = risk of direct or indirect lightning strike
  • Long cable lines: between panels, inverter and switchboard = antennae that pick up surges
  • Sensitive electronics: inverters, batteries, monitoring systems = very vulnerable to voltage peaks
  • Cost of equipment: inverter 2000-5000€, batteries 5000-15000€ = investment that absolutely must be protected

💡 Normative obligation: According to standard NF C 15-100 (section 443) and the Belgian RGIE (article 4.4.4), the installation of lightning arresters is mandatory in certain cases:

  • Buildings equipped with lightning conductors
  • Overhead power supplies in lightning risk zones (AQ2, AQ3, AQ4)
  • Structures open to the public
  • Photovoltaic installations (recommended by guide UTE C 15-712-1)






Typical applications for the Citel DS240S-230 lightning arrester

  • Residential and tertiary photovoltaic installations: protection on the AC side between inverter and main switchboard
  • AC protection cabinets: integration in single-phase or three-phase cabinets
  • Distribution boards: protection at the head of the main or sub-distribution board
  • Heat pumps: protection for exposed outdoor equipment
  • EV charging stations: securing outdoor wallboxes
  • Commercial buildings: protection of sensitive electrical networks






Technical specifications



Paramètre Valeur
Fabricant Citel (Groupe Servalec)
Référence fabricant DS240S-230
EAN-13 0712971139411
Gamme DS2 (Déconnecteur Série 2)
Type de parafoudre Type 2 / Classe II (protection intermédiaire)
Configuration 2P (bipolaire : L-N ou L1-L2)
Technologie Varistances à oxyde métallique (MOV)
Courant de décharge maximal (Imax) 40 kA (8/20 µs) par pôle
Courant de décharge nominal (In) 20 kA (8/20 µs) par pôle
Niveau de protection (Up) ≤ 1,5 kV (L-N) / ≤ 2,5 kV (L-PE, N-PE)
Tension maximale de service continue (Uc) 255 V AC (L-N) / 440 V AC (L-L)
Tension assignée 230 V AC monophasé / 400 V AC biphasé
Fréquence 50/60 Hz
Courant de fuite (à Uc) < 1 mA
Temps de réponse < 25 ns (nanoseconde)
Déconnecteur thermique intégré Oui (déconnexion automatique en fin de vie)
Indicateur visuel d'état Voyant vert = actif / Voyant rouge = défaut/fin de vie
Contact auxiliaire 1 contact sec inverseur (NO/NC) pour signalisation à distance (optionnel selon modèle)
Section de raccordement Rigide : 1,5 à 25 mm² / Souple : 1,5 à 16 mm²
Couple de serrage 2,5 N.m
Montage Rail DIN 35 mm
Largeur (modules 9mm) 2 modules (18 mm)
Dimensions (H x L x P) 85 mm x 18 mm x 65 mm
Poids 0,120 kg
Degré de protection IP IP20 (face avant)
Classe de protection Classe I (mise à la terre obligatoire)
Température de fonctionnement -40°C à +85°C
Humidité relative 0 à 95% (sans condensation)
Altitude max 4000 m
Normes NF EN 61643-11 (IEC 61643-11), NF C 15-100
Certifications CE, NF, marque Citel (qualité française)
Durée de vie Jusqu'à 20 ans (selon exposition et entretien)
Pays de fabrication France 🇫🇷






Why choose the Citel DS240S-230 surge protector?



1. Type 2: high-performance intermediate protection

The Type 2 surge protector (formerly Class II) is the mandatory level of protection at the head of the switchboard according to NF C 15-100. It protects against :

  • Indirect lightning strikes: surges induced by lightning falling nearby (radius 500m-1km)
  • ✅ Manoeuvring overvoltages: mains switching, external short-circuit, sudden load variations
  • ✅ Propagated overvoltages: surges rising from the distribution network



2. 40kA discharge capacity: safe sizing

With an Imax of 40kA (8/20µs) and an In of 20kA, this arrester offers:

  • Comfortable safety margin: capable of absorbing significant overvoltages without degradation
  • Extended service life: withstands several successive events before replacement
  • Standards compliance: exceeds minimum NF C 15-100 requirements (In ≥ 5kA for Type 2)



3. 2P configuration: single-phase and two-phase versatility

The 2-pole model protects :

  • Single-phase installations: protection L-N (phase-neutral) + PE earthing
  • 400V two-phase installations: L1-L2 protection (2 phases) + PE earthing
  • Specific circuits: protection of a dedicated circuit (e.g. PV inverter, VE terminal)



⚠️ Important note: For three-phase installations (3P+N), use the Citel DS240S-400 4-pole model (3P+N).



4. Integrated thermal disconnector: maximum safety

In the event of varistor ageing or failure, the automatic thermal disconnector:

  • Isolates the faulty arrester: avoids any risk of overheating or fire
  • Maintains continuity of service: the installation remains powered (but unprotected → immediate replacement required)
  • ✅ Visual signalling: red LED + dry contact option for remote alarm.



5. Protection level Up ≤ 1.5 kV: electronic safety

The protection level (Up) represents the maximum residual voltage allowed to pass through the arrester. With Up ≤ 1.5 kV:

  • Effective protection of PV inverters: typical withstand range 2-4 kV → comfortable safety margin.
  • ✅ Lithium battery safety: BMS (Battery Management System) protected against voltage peaks.
  • ✅ S ensitive electronic equipment: monitoring systems, smart meters, home automation boxes



6. Response time < 25 ns: ultra-fast protection

MOV varistor technology enables a response in less than 25 nanoseconds:

  • Instant interception: the surge is clipped before it reaches sensitive equipment
  • Complete protection: no time window for exposure



7. Citel French manufacturing: quality and expertise

Citel (Servalec group) has been the French leader in lightning protection since 1986:

  • French manufacturing: design, production and quality control in France
  • Recognised expertise: over 35 years' experience in lightning protection
  • NF certifications: compliance with the most demanding French standards
  • Technical support: full documentation, technical assistance available






Installation and sizing



Installation rules in accordance with NF C 15-100

Règle Prescription
Emplacement En tête de tableau, après disjoncteur général ou disjoncteur d'abonné
Protection amont Disjoncteur ou fusible : 32-63A courbe C (selon puissance installation)
Câblage Câbles courts et droits : longueur totale L ≤ 0,5 m (aller + retour)
Section conducteurs L/N : 6-10 mm² cuivre / PE : 6-16 mm² cuivre (min 6 mm²)
Mise à la terre Connexion PE obligatoire, résistance terre ≤ 30 Ω (idéal ≤ 10 Ω)
Cascade Type 1 + Type 2 Si parafoudre Type 1 en amont : distance ≥ 10m ou découplage inductif
Signalisation Voyant visible + étiquette identification claire



⚠️ Crucial rule: wiring length

The total length of conductors between the arrester and the connection point must be ≤ 0.5 metres (outward + return). Why must this be the case?

  • Each metre of cable adds ~1 µH of inductance
  • Inductance = rise in residual voltage during rapid discharge (high dU/dt)
  • Cable too long = degraded level of protection (Up increases)

💡 Tip: prefer "V" or "T" connections rather than straight lines to minimise lengths.



Sizing according to type of installation

Installation Parafoudre AC recommandé Parafoudre DC (côté PV)
PV résidentiel 3-6 kW mono Citel DS240S-230 (2P 40kA) ✅ Parafoudre DC Type 2 (si câbles longs)
PV résidentiel 8-12 kW mono Citel DS240S-230 (2P 40kA) ✅ Parafoudre DC Type 2 recommandé
PV résidentiel 10-20 kW tri Citel DS240S-400 (4P 40kA 3P+N) Parafoudre DC Type 2 obligatoire
Borne de recharge VE mono Citel DS240S-230 (2P 40kA) ✅ N/A
Pompe à chaleur mono/tri Selon configuration (2P ou 4P) N/A



Checking and maintenance

  • Monthly visual check: green light on (lightning arrester operational)
  • Annual test: check PE continuity, tighten terminals (torque 2.5 N.m)
  • After a violent storm: visual check + electrical test (measure insulation resistance)
  • Immediate replacement if: red light, disconnector tripped, traces of overheating

📅 Lifespan: A well-installed lightning arrester that is subjected to little stress can last 15-20 years. In areas with high thunderstorm activity (>25 days/year), lifespan is reduced to 8-12 years.






Integration into the Wattuneed ecosystem

The Citel DS240S-230 surge protector integrates perfectly into Wattuneed's photovoltaic and protection solutions:

  • Wattuneed AC protection cabinets: pre-equipped installation with integrated surge arrester
  • Solar inverters: essential protection for Deye, Huawei, Solis, Growatt inverters, etc.
  • Storage batteries: securing BMS and management electronics (Pylontech, BYD, Dyness)
  • Monitoring systems: protection of communication modules (Wi-Fi, 4G, Ethernet).




🎯 In summary: your advantages with the Citel DS240S-230 surge protector

  • High-performance protection: Type 2, 40kA Imax, Up ≤ 1.5 kV
  • ✅ 2 P configuration: single-phase (L-N) or two-phase (L1-L2) 230/400V
  • ✅ Maximum safety: thermal disconnector + visual signalling
  • Ultra-fast response: < 25 ns, instant protection
  • Citel French manufacturing: quality, expertise, NF certifications
  • ✅ S tandards compliance: NF EN 61643-11, NF C 15-100, RGIE
  • Durability: 15-20 year service life, manufacturer's warranty
  • ✅ S imple installation: 35mm DIN rail, 2 modules (18mm), quick wiring



Don't let lightning destroy your photovoltaic investment. Protect your inverters, batteries and electronic equipment with the Citel DS240S-230 lightning arrester, the French benchmark for lightning protection. ⚡🛡️



Wattuneed, your partner for secure, long-lasting photovoltaic installations. 🌞⚡