0
    Victron MultiPlus-II 12/24/48 V 3000
    Victron MultiPlus-II 12/24/48 V 3000
    Victron MultiPlus-II 12/24/48 V 3000

    Victron MultiPlus-II 48V 8000-10000

    €3,332.34
    Tax included
    PMP482805000
    0768563817229

    The MultiPlus-II combines the functions of the MultiPlus and MultiGrid.
    It presents all the functions of the MultiPlus, with an external current transformer option to implement the functions of PowerControl and PowerAssist, and to optimize self-consumption with an external current probe (32 A max.).
    It also has all the functions of the MultiGrid with a system against islanding and a long list of certifications for many countries that continues to grow.
    Note: For a while, this product was called MultiGrid-II.

    100% secure payments
    Victron Multiplus II: 48/8000/110-100
    Last items in stock

    Victron MultiPlus-II 48V...

    €3,332.34

    MultiPlus-II Converter / Charger

     

    A MultiPlus with ESS (Energy Storage System) functionality

     

    The MultiPlus-II is a multifunctional converter/charger with all the features of the MultiPlus, and an optional external current probe that increases the PowerControl and PowerAssist function to 50 A and 100 A respectively. The MultiPlus-II is ideal for professional marine installations, with sailboats, vehicles and off-grid systems on land.

    It is also equipped with an islanding system and has a long list of certifications for many countries that continues to grow regarding the SSS application. Several system configurations are possible. For more information, refer to the Design and Installation of an ESS System manual.


    PowerControl and PowerAssist – Improved network or generator capacity

     

    It is possible to set a maximum current for the generator or the network. The MultiPlus-II then takes into account the other AC loads and it will only use the excess for the load, thus avoiding any overload of the power supply to the network or generator (PowerControl function).

    The PowerAssist function gives an extra dimension to the powercontrol principle If a high demand for peak power is often required for a short time, the MultiPlus-II will compensate for the lack of power from the generator, dock or network with energy from the battery. And when demand decreases, the excess power will be used to recharge the batteries.


    Solar energy: AC energy available even in the event of a grid failure


    The MultiPlus-II can be used both off-grid and connected to a PV grid or other alternative energy systems. It is compatible with both solar charge controllers and grid-connected converters.


    Two AC outputs


    The main output has an uninterrupted power function. In the event of a network failure or disconnection of the dock or generator power, the MultiPlus-II takes over the supply of the connected loads. This transfer is so fast (less than 20 milliseconds) that the operation of connected computers or other sensitive electronic equipment will not be disturbed.

    The second output is only powered on when AC power is available on the Input of the MultiPlus-II. Charges that would not discharge the battery, such as a water heater for example, can be connected to this output.


    Power multiplied thanks to parallel and three-phase operation (not available for 8 and 10 k models)


    Up to 6 Multi can run in parallel to get more power output. For example, six 48/5000/70 units will provide 25 kW/30 kVA output power and 420 Amps of load capacity.
    In addition to parallel connection, three units of the same model can be configured for three-phase output. But that's not all: up to 6 sets of 3 units can be connected in parallel for a 75 kW / 90 kVA converter and more than 1200 A of load capacity.


    On-site system configuration, monitoring and control


    Settings can be changed in minutes thanks to VEConfigure software (a desktop or laptop computer and MK3-USB interface are required).
    Several control and supervision options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, desktop or laptop, Bluetooth (with an EV electronic key. Optional Smart Bus), Battery Controller, Multi Control Panel.


    Remote configuration and supervision


    Install a Color Control GX or other GX product for connecting to the Internet.
    Operating data may be stored and displayed on our free VRM (Victron Remote Management) website.
    If systems are connected by Ethernet, they can be accessed and configured.


    Standard, mobile or off-grid marine application


    Loads that need to be turned off when AC input power is not available can be connected to a second (not off) output. These expenses will be taken into account by the functions
    PowerControl and PowerAssist to limit the AC input current to a safe value if AC power is available.


    Grid parallel topology with MPPT solar charge controller


    The MultiPlus-II will use data from the AC current probe (to be ordered separately) or the power meter to optimize self-consumption and, if necessary, avoid energy returns to the grid. In the event of a power outage, the MultiPlusII will continue to power critical loads.


    Characteristics

     

    MultiPlus-II12/3000/120-32 • 24/3000/70-32 • 48/3000/35-3224/5000/120-50 • 48/5000/70-5048/8000/110-
    100
    48/10000/140 -100
    PowerControl / PowerAssistYes
    Transfer switch32 A50A100A
    Maximum AC input current32 A50A100A 
    CONVERTER
    DC supply voltage range12V - 9.5–17 V 24 V - 19–33 V 48 V – 38-66 V
    ExitOutput voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0.1% (1)
    Continuous output power at 25°C (3)3000 VA5000 VA8000 VA10000 VA
    Continuous output power at 25°C2400 W4000 W6400 W8000 W
    Continuous output power at 40°C2200 W3700 W5500 W7000 W
    Continuous output power at 65°C1700 W3000 W4000 W6000 W
    Then. of maximum return. Alleged3000 VA5000 VA8000 VA10000 VA
    Peak power5500 W9000 W15000 W18000 W
    Maximum efficiency93 % / 94 % / 95 %96 %95 %96 %
    Unladen consumption13 / 13 / 11 W18 W29 W38 W
    Unladen power consumption in AES mode9 / 9 / 7 W12 W19 W27 W
    Zero charging power in Search mode3 / 3 / 2 W2 W3 W4 W
    CHARGER
    AC inputSupply voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
    "Absorption" charging voltage14.4 / 28.8 / 57.6 V
    Charging voltage "Float"13.8 / 27.6 / 55.2 V
    Storage mode13.2 / 26.4 / 52.8 V
    Maximum battery charging current120 /70 / 35 A120 / 70 A110 A140 A
    Battery temperature probeYes
    GENERAL
    Auxiliary outputYes (32 A)Yes (50 A)
    External current probe AC (optional)50 A100 A
    Programmable relayYes
    Protectiona - g
    EV communication port. BusFor parallel operation (not compatible with 8 and 10 k models) or three-phase, remote control and system integration
    Universal com. portYes, 2x
    Remote on/offYes
    Operating temperature range-40 to +65 °C (fan cooling)
    Humidity (non-condensing)max 95%
    CASE
    Material and colorSteel, blue RAL 5012
    Degree of protectionIP22
    Battery connectionM8 nuts4 M8 bolts (2 positive and 2 negative connections)
    230 VAC connectionScrew terminals 13 mm2 (6 AWG)M6 bolts
    Weight19 kg30 kg42 kg49 kg
    Dimensions (H x W x D) mm546 x 275 x 147,499 x 268 x 141,499 x 268 x 141565 x 328 x 240 560 x 320 x 141642 x 363 x 206677 x 363 x 206
    STANDARDS
    SecurityEN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2
    Emission, ImmunityEN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3