The first 2-in-1 solar inverter and EV charger
SolarEdge's EV Charging single-phase inverter enables owners to charge their electric vehicles directly from the sun's power, maximizing their solar energy consumption and further reducing their electricity bills. They will also benefit from the ability to charge their EVs up to 2.5 times faster than with a standard EV charger, thanks to an innovative "Solar Boost" mode that simultaneously uses grid and PV power.
By installing the EV Charging inverter, you avoid the hassle of separate installation of a stand-alone EV charger, a PV inverter, and then integration with the SolarEdge supervision platform.
Whether your customer owns an electric vehicle today, or simply wants to be ready when the time comes, prepare your business for the future with SolarEdge.
Total visibility and control
SolarEdge's single-phase inverter for electric mobility supports full grid connectivity and seamlessly integrates with the SolarEdge monitoring platform via the Internet. Owners can monitor their charge level, control vehicle charging and set charging schedules.
Supervision features include:
- Intelligent scheduling for time-of-use (TOU) tariffs - billing from the grid during off-peak hours
- Supervision of solar, electricity and grid consumption for visibility and control of household energy consumption
- Remote control via mobile app - activate and deactivate charging
- Display of charging time, charging energy and percentage of solar charge
- Easy inverter commissioning directly via your smartphone using the SetApp mobile app
Key benefits
- Combines solar and grid power for EV charging up to 2.5 times faster than a conventional mode 2 charger
- Maximizes self-consumption and optimizes the use of renewable energy
- Designed to work specifically with SolarEdge power optimizers
- Record 99% efficiency and high reliability, optimized by HD-Wave technology
- Small, lightweight and as easy to install and commission as a standard SolarEdge inverter
- Integrated supervision at module level (a connection to supervision is also required for initial charging of the electric vehicle)
- Advanced safety features, including integrated arc protection
- Flexible selection of charger cable types and lengths (cable and bracket ordered separately)
- Integrated DC-RCD 6mA, compliant with IEC 62752: 2016, for reduced labor and installation costs
VE charger configuration
To configure the VE charger via the SolarEdge monitoring application, an Ethernet or ZigBee® connection is required.
A cellular connection can be used; this requires a SIM card with a 1 GB data rate, which can be obtained from a telephony provider.
Dimensions
Features
Model | SE3680H | SE4000H | SE5000H | SE6000H | Value |
Rated AC output power | 3680 | 4000 | 5000 | 6000 | VA |
Maximum AC output power | 184-.264.5 | Vac |
AC frequency (nominal) | 50/60 +-5 | Hz |
Maximum continuous output current | 16 | 18/05/19 | 23 | 27/05/19 |
Maximum output fault current and duration | 16/20 | 18/05/20 | 23/20 | 27/05/20 | A/ms |
Detector |
detector/Residual current level detector | 300/30 | mA |
AC inrush current (peak/duration) |
8/20 |
(ms) / ms |
Maximum overcurrent protection | 38 |
Power factor range |
(adjustable from -0.9 to +0.9) |
Total harmonic distortion | <3 |
Protection category | Category I |
Supervision of public equipment, islanding protection, |
country-configurable thresholds | Yes |
Maximum DC power | 5700 | 6200 | 7750 | 9300 |
Without trasnformer, |
without ground |
Nominal DC input voltage | 380 |
5
Reverse polarity protection | Yes |
Ground fault insulation detection | 600 kΩ sensitivity |
Maximum inverter efficiency | 99.2 |
Weighted European efficiency | 99 |
Nocture power consumption | < 2.5 |
Installation specifications |
AC output - Supported cable diameter |
AC-Supported cable cross-section | 1-13 | mm² |
DC input |
x MC4 pair |
x MC4 pair |
Dimensions with connection unit (HxWxD) | 450 x 370 x 174 | mm | |
Weight with connection unit | 10 | 11.4 | 11.9 | kg |
Cooling | Natural convection |
Operating temperature range | From -40 to +60 | °C |
Ambient air pressure | Minimum 860hPa - 1060hPa |
Protection class | IP65 - Outdoor and indoor (Inverter with connection unit) |