    Earth leakage circuit breaker 63A Type B
    Earth leakage circuit breaker 63A Type B
    Earth leakage circuit breaker 63A Type B
    Earth leakage circuit breaker 63A Type B
    Earth leakage circuit breaker 63A Type B
    Earth leakage circuit breaker 63A Type B
    Earth leakage circuit breaker 63A Type B

    Earth leakage circuit breaker 63A - 300mA Type B

    €137.09
    Tax included
    TORD4B-63
    0768563819674

    The residual current circuit breaker is applicable to electrical circuits with a rated voltage of 230/400V AC, a frequency of 50/60Hz and a rated current of up to 63A.

    100% secure payments

    Earth leakage circuit...

    €137.09

    Earth leakage circuit breaker 63A - 300mA Type B

    With the diversification of energy use and equipment, the interactive use of alternating and direct current, and products with many different waveform signals, we need higher-level residual current protection circuit breakers to protect our personal safety and avoid the danger of electric shock.


    Type B RCD RCCB General :

    Type B RCDs, in addition to normal alternating current, can detect high-frequency AC and pure DC earth leakage currents.
    Reducing the risk of fire and/or electrocution by automatically disconnecting the power supply relies on selecting the right type of RCCB.
    The RCCB offers mutual protection to the operator's body in conditions where exposed live parts must be connected to a suitable grounding post. The RCCB also offers protection against the fire hazard caused by ground fault current due to a malfunction of the overcurrent protection device.


    Advice:

    1. RCCB with rated sensitivity up to 10mA could be used as an additional protective device in the situation where the protective device fails.
    2. RCCB
    3. designed for domestic installation and similar applications, is generally used for non-professional operation (no maintenance required)
    4. .
    5. RCCB provides protection against electric shock resulting from direct contact of the two protected lines, or leakage current between these two lines.
    6. It is recommended to install special devices such as surge protection devices, a lightning arrester, etc. on the line upstream to the RCCB as a precaution against the potential voltage and surge current occurring at its supply input
    7. .

    Features

    ModelElectromagnetic type
    Residual current characteristic:Type B
    No. of poles:2P
    Rated manufacturing and breaking capacity630A
    Rated current(A)16-63A
    Rated voltage230V / 400V
    Rated frequency50 / 60Hz
    0
    Rated residual operating current |△(A) :
    .03, 0.1, 0.3
    0
    Rated residual non-operating current |△ no :
    .5|△n
    6kA
    Rated conditional short-circuit current inc:
    6kA
    Rated conditional residual short-circuit current |△c:
    Tripping duration:Instantaneous tripping ≤0.1s
    0
    Residual tripping current range:
    .5||△n~|△n
    Electromechanical endurance≥5000 XNUMX cycles
    Connection capacity:Rigid conductor 25mm²;
    Connection terminalscrew terminal
    Column terminal with clamp
    3
    Tightening torque
    .5 Nm
    InstallationOn 35 mm symmetrical DIN rail
    Panel mounting
    TORD4B-63
    253 Items

    Data sheet

    Type of electrical equipment
    Disjoncteur

    Specific References

    UPC
    768563819674
    EAN13
    0768563819674
    New

    Download

    Tongou-63A-datasheet-EN