0
    8A timer relay - Crouzet MUR3
    8A timer relay - Crouzet MUR3
    Crouzet MUR3 - Timer relay 8A
    Crouzet MUR3 - Timer relay 8A
    8A timer relay - Crouzet MUR3
    Crouzet MUR3 - Timer relay 8A
    Crouzet MUR3 - Timer relay 8A

    8A timer relay - Crouzet MUR3

    €127.21
    Tax included
    Mur-3-88827103
    0768563816291

    8A timer relay

    100% secure payments

    8A timer relay - Crouzet MUR3

    €127.21

    8A timer relay - Crouzet Mur3

    Relais temporisé 8A - Crouzet MUR3

    ' Multifunction or monofunction
    ' Multi-range (7 switchable ranges)
    ' Multivoltage
    ' Screw or spring-loaded terminals
    ' 1 LED status display (relay version)
    ' Possibility of supplying a load in parallel
    ' 3-wire sensor control possible


    Dimensions

    Dimensions


    Output 1 changeover relay

    Sortie 1 relais inverseur


    Features

    Caractéristiques

    Specifications
    A
    Functions
    - Ac - At - B - Bw - C - D - Di - H - Ht
    0
    Time delay
    ,1 s →100 h
    1
    Output
    changeover relay
    8
    Rated current
    A
    ConnectionsScrew terminals
    Supply voltage12 →240 V∿/⎓
    Order no.
    Timer
    1
    Timer ranges (7 ranges)
    s - -
    10 s - 1 min - 10 min - 1 h - 10 h - 100 h
    Repetition accuracy (at constant parameters)± 0,5 % IEC/EN 61812-1
    drift
    Temperature
    ± 0.05 % / °C
    drift
    Voltage
    ± 0.2 % / V
    Display accuracy according to IEC/EN 61812-1± 10 % / 25 °C
    Micro-break immunity time :typical<
    10 ms
    Typical minimum pulse duration (relay version)30 ms
    Typical minimum pulse duration (static version)50 ms
    Typical minimum pulse duration (relay version with load)100 ms
    voltage interruptiont
    Max. reset time per
    ypical voltage failure (relay version)120 ms
    Max. reset time per typical voltage failure (static version)350 ms
    Multi-voltage supplyAccording to version
    Frequency (Hz)50/60
    Duty
    cycle100,00%
    Operating range85 →110% Un
    85 →120% Un for 12 V ∿/⎓
    Max. power consumption32 VA (240 V∿) - 1,5 W (240 V⎓) - 0.6 W (24 V⎓) - 0.7 VA (12 V∿) - 0,7 W (12 V⎓)
    elements
    Output
    capacity
    Breaking
    2000 VA/80 W
    8
    Maximum breaking capacity
    A∿ 250 V∿ resistive -
    8 A⎓ 30 V⎓ resistive
    Minimum breaking current10 mA / 5 V⎓
    Maximum breaking voltage250 V∿ / 8 A∿ resistive 250 V⎓ / 0,3 A resistive
    8
    Electrical life (switching)10⁵
    A 250 V∿ resistive
    Mechanical life (switching)10 x 10⁶
    2
    Dielectric strength to IEC/EN 61812-1
    ,5 kV / 1 min / 1 mA / 50 Hz
    5
    Shock voltage to IEC/EN 60664-1, IEC/EN 61812-1
    kV - wave 1.2/50 μs
    General characteristics
    Conformity to standardsIEC/EN 61812-1,
    IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4
    CertificationsCE, UL, cUL, CSA,
    GL
    -20
    Limiting temperatures for use (°C)
    →+60
    -30
    Limiting temperatures for storage (°C)
    →+60
    Installation category (according to IEC/EN 60664-1)Overvoltage category III
    4
    Leakage paths and clearance to air according to IEC/EN 60664-1
    kV / 3 mm
    Degree of protection (IEC/EN 60529)IP20
    IP40
    Degree of protection (IEC/EN 60529) Front panelIP50
    resistance
    Vibration
    to IEC/EN 60068-2-620 m/s² 10 Hz →150 Hz
    Relative humidity to IEC/EN 60068-2-30 non-condensing93% non-condensing
    Electromagnetic compatibility -
    Immunity to electrostatic discharge to IEC/EN 61000-4-2Level III (Air 8 kV/contact 6 kV)
    Immunity to electromagnetic fields to IEC/EN 61000-4-3Level I - (1 V/m : 2.0 G Hz â†'2.7 G Hz) Level II - (3 V/m : 1.4 G Hz →2.0 G Hz) Level III - (10 V/m :
    80 M Hz →1 G Hz)
    Immunity to fast burst transients to IEC/EN 61000-4-4Level III (direct 2 kV/Capacitive coupling clamp 1kV)
    .
    Immunity to power-supply shock waves to IEC/EN 61000-
    4-5Level III (common mode 2 kV/differential mode 1 kV)
    Radio frequency immunity in common mode to IEC/EN 61000- 4-6Level III (10V rms :
    0.15 M Hz to 80 M Hz)
    Voltage dip and cut immunity to IEC/EN 61000-4-110% residual voltage, 1 cycle
    70% residual voltage, 25/30 cycles
    Mains and radiated emissions to EN 55022 (CISPR22), EN55011 (CISPR11)Class B
    Mounting :
    DIN rail symmetrical35 mm
    1
    Clamping capacity Single-strand without ferrule
    x 0.5 →3.3 mm² - (AWG 20 →AWG 12) 2 x 0.5 →2.5 mm² - (AWG 20 →AWG 14)
    1
    Clamping capacity Stranded with ferrule
    x 0.5 →2.5 mm² - (AWG 20 →AWG 14) 2 x 0.5 →1,5 mm² - (AWG 20 →AWG 16)
    Housing materialSelf-extinguishing
    Shock test to IEC/EN 60068-2-2715 g - 11 ms
    0
    Brief voltage interruptions to IEC/EN 61000-4-11
    % residual voltage, 250/300 cycles
    2
    Spring-loaded terminals,
    2 terminals per connection point - flexible wires
    x 0.5 →1.5 mm² - (AWG 20 →AWG 16)
    2
    Spring-loaded terminals, 2 terminals per connection point - rigid wires
    x 0.5 →1.5 mm² - (AWG 20 →AWG 16)
    Ground
    :17.5 mm case88827105 (MUR1) : 63 g 88827115 (MAR1) : 63 g 88827125 (MBR1) : 63 g 88827135 (MCR1) : 62 g 88827145 (MHR1) : 63 g 88827150 (MLR4) : 63 g 88827155 (MLR1) : 64 g 88827100 (MUR4) :
    62 g 88827103 (MUR3) : 66 g 88827503 (MURc3) : 59 g
    Insulation resistance to IEC/EN 60664-1100 MΩ (500 V ⎓)
    element
    Output
    Relay 1 or 2 AgNi (cadmium-free) changeover switches1 C/O
    Mur-3-88827103
    449 Items

    Specific References

    UPC
    768563816291
    EAN13
    0768563816291
    New

    Download

    F.Tech Mur3 Relais(FR)

    Download (451.52KB)

    Datasheet Mur3 Timed Relay(En)

    Download (482.9KB)