ABB ACS355 frequentieregelaar voor zonne-energiepompen - 400 V driefasig
ASC355 speed variator for solar pumping.
This model is intended to power 400Volts three-phase pumps.
ABB has specifically developed a range of dimmers for solar pumping applications. The ABB ACS355 frequency dimmers are equipped with software suitable for solar pumping.
ASC355 speed variator for solar pumping

Functional, compact and economical
The ACS355 ABB frequency dimmers are quick to install, set up and put into service.
Very compact and economical, their functional intelligence and high level of security will meet the highest demands for productivity and performance.
These dimmers can be adjusted according to the characteristics of the engine of the pump to be powered.
This model is intended to power 400Volts three-phase pumps.
Applications
The ACS355 is designed to control 400V three-phase pumps. They are equipped with a progressive start function and a detection of dry operation. They protect the engines perfectly from the pumps.
Key points
- Exceptional compactness and streamlined dimensions.
- Quick commissioning with application macro programs and micro-console assistants.
- Secure stop STO (Safe torque-off, SIL3) as standard.
- Vector control without a sensor.
- Built-in braking chopper.
- Micro-console debugging and compatible with the upper range ACS550.
- ENHANCEd PROTECTION variants IP66 for difficult environments (optional).
Characteristics
| Characteristics | Benefits | Remarks |
| availability and technical support | Divariators are available at all times. Dedicated network of services and technical support among the most extensive on the market |
Fast and reliable delivery Provides services and technical support in every country in the world |
| Widest power range in its class (0.37 to 19 kW) | The range covers a very wide range of power | Reducing the costs of machine manufacturers |
| Compactness and rationalization of dimensions | Highest power density in the category (2.8 kW/dm3) Same depth and height for the whole range Simplification of cabinet editing and multivariator applications |
Saving space in tight spaces |
| Secure shutdown STO (SIL3) as standard | Integrated and STO-certified function (Safe torque-off) Preventing untimely start-ups and different types of stops |
Fewer external security components Compliance with the requirements of the Machinery Directive 2006/42/EC by machine manufacturers |
| Programming | Programming in minutes. the software is pre-pogrammé for solar pumping | Avoids using an external automaton (API) |
| Macroprograms and commissioning assistants | Preconfiguration of macroprogram E/S (e.g., 3-wire command, motopotentiometer) Assisted adjustment of many functions: start-up, engine data setting0 |
Rapid commissioning of the dimmer |
| FlashDrop box |
Loading a set of parameters (among about 20) in a dimmer not connected to the network in a matter of seconds |
Rapid, easy and reliable predictor of dimmers by large-series machine manufacturers |
| IP66/67/UL Type 4X protection variant for challenging environments |
No special envelopes to use for environments that require enhanced protection. NSF-certified variator |
Saving time and money |
MCU Update Procedure voor Omvormers
Professionele Versie - Technisch Document
Dit document beschrijft de volledige procedure voor het uitvoeren van een Microcontroller (MCU) update op omvormers. Deze operatie is essentieel voor het behouden van optimale apparaatprestaties en het integreren van de nieuwste software-verbeteringen.
Een correct uitgevoerde update garandeert de juiste werking van de omvormer en verlengt zijn levensduur. Het is cruciaal om deze procedure stap voor stap te volgen om storingen te voorkomen.
KRITIEKE AANDACHT
Een onderbroken update kan de omvormer onbruikbaar maken.
Koppel tijdens de procedure niet de stroomvoorziening van de computer of omvormer los.
Vermijd het in slaapstand zetten van de computer tijdens de update.
Zorg ervoor dat de batterij van uw computer voldoende opgeladen is of dat de computer op netstroom aangesloten is.
Maak een back-up van alle belangrijke gegevens voordat u met de procedure begint.
Benodigde Hardware
Benodigde Software
Voorafgaande Controles
1 Voorbereiding van de Omvormer
Stop bepaalde functies van de omvormer:
Controleer de status van de omvormer:
2 Verbinding van Computer naar Omvormer
Sluit de USB-kabel aan op de computer:
Identificeer de toegewezen COM-poort:
Sluit het andere uiteinde van de kabel (RJ45) aan op de COM-poort van de omvormer:
3 MCU Update
Start de update software:
Configuratie van de software:
Initiatie van de update:
Monitoring van de update:
Voltooiing van de MCU update:
4 DSP Update (indien nodig)
Voorbereiding voor DSP update:
DSP update procedure:
Versie Controle
Functionele Test
De omvormer detecteert de verbinding niet
Update mislukking
De computer herkent het apparaat niet
MCU
Microcontroller, het hoofd "brein" van de omvormer
DSP
Digital Signal Processor, gespecialiseerde processor voor signaalverwerking
COM Poort
Seriële communicatiepoort gebruikt voor verbinding tussen computer en omvormer
RS232
Seriële communicatiestandaard voor gegevensoverdracht
Contact Technische Ondersteuning
In geval van aanhoudende moeilijkheden of technische vragen, staat ons ondersteuningsteam tot uw beschikking:
Houd alstublieft uw exacte omvormer model en eventuele foutcode bij de hand bij contact.
ABB ACS355 frequentieregelaar voor zonne-energiepompen - 400 V driefasig — Accessories
ABB ACS355 frequentieregelaar voor zonne-energiepompen - 400 V driefasig by ABB is available in our Accessories catalog. Product weight: 1.3 kg. Referentie: 0799.