Victron Phoenix 12V / 24V / 48V - 375VA

Phoenix VE.Direct 12/24/48 375VA inverter. 

Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications.

logo victron energy

 

More info

More details

150,04 €

Options

Add to cart

By buying this product you can collect up to 16 loyalty points. Your cart will total 16 points that can be converted into a voucher of 4,80 €.


More info

convertisseur phoenix victron

VE.Direct communication port


The VE.Direct port can be connected to:

• A computer (VE.Direct to USB interface cable needed)

• Apple and Android smartphones, tablets, macbooks and other devices (VE.Direct Bluetooth Smart dongle needed)

Fully configurable:

• Low voltage alarm trip and reset levels

• Low voltage cut-off and restart levels

• Output voltage 210 - 245V

• Frequency 50Hz or 60Hz

• ECO mode on/off and ECO mode sense level

Monitoring:

• In- and output voltage and current alarms

Proven reliability

The full bridge plus toroidal transformer topology has proven its reliability over many years. The inverters are short circuit proof and protected against overheating, whether due to overload orhigh ambient temperature.



High start-up power

Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.



ECO mode

When in ECO mode, the inverter will switch to standby when the load decreases below a preset value. Once in standby the inverter will switch on for a short period (adjustable, default: every 2,5seconds). If the load exceeds a preset level, the inverter will remain on.



Remote on/off

A remote on/off switch can be connected to a two pole connector, or between battery plus and the left hand contact of the two pole connector.



LED diagnosis

Please see manual for a description.



To transfer the load to another AC source: the automatic transfer switch

For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features avery short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.





Technical data

Phoenix inverter 12/375 24/375 48/375
Cont. power at 25°C375
Cont. power at 25°C / 40°C300 / 260
Peak power (W)700
Output AC voltage / frequency (adjustable)230 V CA ±3 % 50 Hz ou 60 Hz ±0,1 %
Input voltage range9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0 V
DC low restart and alarm (adjustable)10,9 / 21,8 / 43,6
DC low shut down (adjustable)9,3 / 18,6 / 37,2 V
Battery charged detect (adjustable)14,0 / 28,0 / 56,0 V
Max. efficiency 12 / 24 / 48 V (%)89 / 89 / 90 %
Zero-load power5,6 / 6,1 / 8,5W
Default zero-load power in ECO mode(default retry interval: 2,5 s, adjustable)0,9 / 1,4 / 2,6 W
ECO mode stop and start power settingAdjustable
Operating temperature range-40 to +65°C (fan assisted cooling) (derate 1,25% per °C above de 25°C)
Humidity (non-condensing)max 95%
Enclosure
Material & ColourSteel chassis and plastic cover (blue Ral 5012)
Battery-connectionScrew terminals
Standard AC outletsSchuko (CEE 7/4), IEC-320 (male plug included)UK (BS 1363), AU/NZ (AS/NZS 3112)
Remote on-off

Yes

Protection categoryIP 21
Poids kg3,0
Dimensions (HxLxP, mm)86x165x260
SafetyEN/IEC 60335-1 / EN/IEC 62109-1
EMCEN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-3

Specifications

Inverter power- de 1000VA