1
    Victron MultiPlus-II 48 V 3000 and 5000VA
    Victron MultiPlus-II 48 V 3000 and 5000VA
    Victron MultiPlus-II 48 V 3000 and 5000VA

    Inverter/Charger Victron MultiPlus-II GX 48V 3000/5000

    €1,009.14
    Tax included
    PMP482306000
    0768563817229

    MultiPlus-II combines the functions of MultiPlus and MultiGrid.
    It features all the functions of the MultiPlus, with the option of an external current transformer to implement PowerControl and PowerAssist functions, and to optimize self-consumption with an external current probe (max. 32 A).
    It also features all MultiGrid functions, with anti-islanding and a long and growing list of certifications for many countries.
    Note: for some time, this product was called MultiGrid-II.

    100% secure payments
    Victron Multiplus II: GX 48/3000/35-32

    Inverter/Charger Victron...

    €1,009.14

    Victron

    New 48 V converter/charger


    A MultiPlus-II with LCD display and GX functionality


    The MultiPlus-II GX integrates a MultiPlus-II converter/charger and a GX device with a 2 x 16-character display.


    Display and Wi-Fi


    The display reads the parameters of the solar charge controller, battery and inverter.
    The same parameters can be accessed from a smartphone or device with Bluetooth enabled.


    GX device


    The integrated GX device includes :
    - BMS-Can interface. It can be used to connect to a bus-Can compatible battery. Note that this is not a VE.Can-compatible port.
    - USB port.
    - Ethernet port.
    - One VE.Direct port.


    Applications


    The MultiPlus-II GX is designed for applications requiring additional interfacing with other products and/or remote supervision, such as on-grid or off-grid energy storage systems and certain mobile applications.


    Parallel or three-phase operation


    Only one GX unit is required for parallel or three-phase operation


    Standard marine, mobile or off-grid application


    Loads that need to be switched off when AC input power is not available can be connected to a second output (not switched off). These loads will be taken into account by the PowerControl and PowerAssist functions to limit the AC input current to a safe value if AC power is available.

    Schéma Application marine standard, mobile ou hors-réseau


    Standard mobile or off-grid application with external current sensor


    Maximum current detection range: 50 A and 100 A, respectively.

    Schéma Application mobile standard ou hors réseau avec une sonde de courant externe


    Grid-parallel topology with MPPT solar charge controller


    The MultiPlus-II will use data from the AC current sensor (to be ordered separately) or from the power meter to optimize self-consumption and, if necessary, avoid energy feed-backs to the grid. In the event of a power failure, the MultiPlus-II will continue to supply critical loads.

    Schéma: Topologie parallèle au réseau avec le contrôleur de charge solaire MPPT


    On-grid topology with PV inverter


    PV power is converted directly to AC.
    The MultiPlus-II will use excess PV power to charge the batteries or return energy to the grid, and will discharge the batteries or use grid energy in the event of a shortage of PV energy. In the event of a power failure, the MultiPlus-II will disconnect from the grid and continue to supply loads.

    Schéma: Topologie en ligne sur le réseau avec un convertisseur PV


    Features

    MultiPlus-II GX48/3000/35-32
    48/5000/70-50
    PowerControl / PowerAssistYes
    Transfer switch32 A50 A
    Maximum AC input current32 A50 A
    Auxiliary outputYes (32 A)
    CONVERTER
    DC supply voltage range19 - 33V38 - 66 V
    OutputOutput voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0.1% (1)
    Continuous output power at 25°C3000 VA5000 VA
    Continuous output power at 25°C2400 W4000 W
    Continuous output power at 40°C2200 W3700 W
    Continuous output power at 65 °C1700 W3000 W
    Assumed max. return power3000 VA5000 VA
    Peak power5500 WW
    Maximum efficiency95%96
    No-load power consumption11 W18 W
    No-load power consumption in AES modeW12 W
    Zero charge power in Search modeW
    CHARGER
    AC inputSupply voltage range: 187-265 VAC Input frequency: 45 - 65
    Absorption charging voltage57.6 V
    Float charge voltage55.2 V
    Storage mode52.8 V
    Maximum battery charging current35 A70 A
    Battery temperature sensorYes
    GENERAL
    Interfaces, USB, Ethernet, VE.Direct, Wi-Fi
    External AC current sensor (optional)50 A100A
    Programmable relayYes
    Protection- g
    VE.Bus communication portFor parallel or three-phase operation, remote control and system integration
    Universal com. portYes, 2x
    Remote on/offYes
    Operating temperature range40 to +65°C (fan cooled)
    Humidity (non-condensing)max. 95
    CASING
    Material and colorSteel, blue RAL 5012
    Degree of protectionIP22
    Battery connectionM8 bolts
    Connection 230 VACScrew terminals 13 mm² (6 AWG)
    Weight19 kg30 kg
    Dimensions (H x W x D) mm506 x 275 x 147x 323 x 148
    Standards
    SafetyEN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2
    Emission, ImmunityEN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3