UPS Vision Spirit II inverter 6 and 10Kva

Vision Spirit II inverter 6Kva and 10Kva (96,108,120VDC)

logo ups vision

More details

2 644,00 €

Options

By buying this product you can collect up to 325 loyalty points. Your cart will total 325 points that can be converted into a voucher of 97,50 €.


Shipping fee preview
More info

" 6000 and 10000 VA "

 

On line type (also called double conversion )

schema onduleur onlineThis UPS operates a double conversion 

- In normal mode, the UPS inverter is placed between the network and the load. The power supplied to the consumers goes constantly through the UPS which carries a double conversion AC / DC and DC / AC .

- In standalone mode , the battery supplies power to the inverter and the inverter supplies power to the load. This configuration is the most expensive but also the most comprehensive in terms of the protection of the load. The inverter converts continuously the voltage of the grid, allowing precise control of the voltage and frequency of the output . Given the isolation of consumers over the electric grid, power system disturbances are eliminated at the UPS output

 

Furthermore, the transition from normal mode to autonomous mode is instant without any swapping delay . The UPS directs the load to the network using a static bypass contactor in caseof a failure or battery discharge. The UPS is synchronized with the grid, the transfer is carried out without break. This UPS is the best protection against interference and micro-breaks for sensitive equipment.

 

 

Description

onduleur spirit II

  • On-line„Double conversion“ technology (VFI)
  • DSP (Digital Signal Processor) technology
  • Internal static and manual bypass in dismountable module
  • Input Power Factor up to 0.99
  • Wide input voltage range
  • Rack / Tower (XL design) 
  • Up to 4 units in parallel 
  • Battery (DC) cold start 
  • ECO-Mode for energy saving
  • Site wiring fault indication 
  • Self testing when UPS startup

Protections

 
  • RJ45 / 11 network protection
  • Intelligent managment through RS232 & USB
 
 
Warranty
 
  • 2 years (electronics)



 
 
 
 
 
 
 
 
 
 
 

 

Specifications

Model6000VA10000VA
Power5400W9000W
Input
Minimum voltage120VAC   
Maximum voltage 276VAC
Frequency 40Hz-70Hz (auto sensing)   
Input power factor 

?0.99 

Bypass voltage range 

-45% / +15%

Harmonic distortion (THD) 

?5% at 100% non-linear load 

Output    
Voltage220/230VAC   
Waveform Pure sine wave   
Harmonic distortion (THD) <2% at 100% linear load   
Frequency 

+- 1/2/4/5/10% of the rated voltage (optional) / 50Hz +-0,2% (Battery mode) 

Voltage stabilization +- 2%   
Crest factor 3:1   
Efficiency 90% (Normal mode) / 98% (Eco mode)  
Protection    

Overload Capacity 

?110% load 60min, ?125% load 10min, ?150% load 1min 

Input / Output protection against Overload - Temperature - Short circuit   
Alarms - Informations
Audible alarm Beeping sound for battery backup, battery low, overload status, fault status   
LED alarm Mains, inverter, bypass, fault, battery level   
LCD display Input and output voltage, load, battery voltage, error codes   
Bypass    
TypeInternal static automatic and manual bypass / External bypass optional   
 
  
Environment    
Temperature / altitude / Humidity 0-40°C / less than 1500m / 0-95% non-condensing
Audible noise at 1m < 50dBA
Interface    
Standard

RS232 / RS485 (software included)

Optional 

SNMP card / Parallel card / Centralized monitoring card / Relay card

Dimensions    
Weight 20kg30kg 
WxDxH

250x590x655mm

Specifications
Power6000 VA à 10000 VA