1
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20
    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20

    MPPT controller Victron SmartSolar 75/10-15 & 100/15-20

    €79.86
    Tax included
    10059
    0712971136236

    Ultra-fast, highly efficient 12/24V Maximum Power Point Tracking (MPPT) solar charge controller: optimum performance, optimized performance in partial shading, programmable battery algorithms ...

    100% secure payments
    Charge controller Victron SmartSolar Models: SmartSolar MPPT 12/24V 75/10

    MPPT controller Victron...

    €79.86

    Victron

    SmartSolar is packed with features and options. These ultra-fast, highly efficient Maximum Power Point Tracking (MPPT) solar charge controllers have it all: optimum performance, partial-shade performance optimization, programmable battery algorithms, street lighting functions and more. Smart is designed with integrated Bluetooth for monitoring and control with VictronConnect. Options include remote monitoring over the Internet via the VRM portal, also a plug-in LCD display for larger models.

    VE.Direct

    For wired data connection to a Color Control panel, PC or other devices.

    Ultra-fast MPPT tracking

    When light intensity is constantly changing, especially under cloudy skies, a fast MPPT algorithm will improve energy harvesting by up to 30% compared to PWM (pulse width modulation) charge controllers, and by up to 10% compared to slower MPPT controllers.

    Load output

    Excessive battery discharge can be prevented by connecting all loads to the load output. The load output will disconnect the load when the battery has been discharged to a predetermined voltage. Alternatively, an intelligent battery management algorithm can be selected: BatteryLife. The charging output is protected against short-circuits. Loads with a high inrush current are best connected directly to the battery. If they have a remote ON/OFF input, these loads can be controlled by connecting the controller's load output to this input.

    BatteryLife: intelligent battery management

    When a solar charge controller can't fully recharge the battery in a single day, the result is often that the battery constantly alternates between a "partly charged" and an "end-of-discharge" state. This mode of operation (non-regular full recharge) will damage lead-acid batteries within a few weeks or months. BatteryLife's algorithm will monitor the battery's state of charge, and if necessary, slightly increase the charge disconnection level day by day (i.e. disconnect the charge earlier), until the solar energy generated is sufficient to recharge the battery to close to 100% capacity. From then on, the level of load disconnection will be modulated so that a recharge of close to 100% is achieved at least once a week.

    Internal temperature sensor.

    It compensates absorption and float charge voltages according to temperature.

    Automatic battery voltage recognition

    The controller will automatically adjust to a 12 or 24 V system only once. If a different system voltage is required at a later stage, the change will have to be made manually, for example using the Bluetooth application.

    Three-step charging

    The controller is configured for a three-stage charging process: Bulk -
    Absorption - Float.

    Bulk
    During this stage, the controller delivers as much current as possible to rapidly recharge the batteries.

    Absorption
    When the battery voltage reaches the absorption voltage, the controller switches to constant voltage mode. During shallow battery discharges, the absorption charge time is limited to prevent overcharging. After a deep discharge, the absorption period is automatically increased to ensure the battery is fully recharged. The absorption period also ends when the charging current falls below 1A.

    Float
    During this stage, Float voltage is applied to the battery to maintain a full state of charge. When the battery voltage drops below the Float voltage for at least 1 minute, a new charge cycle is triggered.

    Configuration and supervision

    - Bluetooth Smart (integrated): for connection to a smartphone or tablet running iOS or Android.
    - Use the VE.Direct-USB cable (ASS030530000) to connect to a PC, a smartphone
    Android smartphone and On-The-Go USB stick (OTG USB cable required).
    USB cable required).
    - Use a VE.Direct-VE.Direct cable to connect to the MPPT Control or a Color Control panel.

    SmartSolar Charge ControllerMPPT 75/10MPPT 75/15MPPT 100/15MPPT 100/20
    Battery voltageAutomatic selection 12/24 V
    Maximum battery current10 A15 A15 A20 A
    PV power rating,

    1

    2 V 1a, b)145 W220 W220W290W
    PV rated power, 24 V 1a, b)290 W440 W440W
    Max.
    PV short-circuit current 2)13 A15 A15A20A
    Automatic load disconnectionYes, maximum load 15 AYes,
    maximum load 20 A
    Maximum PV open-circuit voltage75 V maximum under cold conditions
    74 V for start-up and normal operation
    100V100V
    Peak efficiency98%
    Self-consumption10 mA
    "Absorption" charging voltage14,4 V/28.8 V (adjustable)
    "Equalization" charging voltage16.2 V/32.4 V (adjustable)
    "Float" charging voltage13.8 V/27.6 V (adjustable)
    Charging algorithmAdaptive multi-step or user-defined algorithm
    Temperature compensation
    mV / °C resp.
    -32 mV / °C
    Continuous charging current15 A20 A
    Reduced voltage charge disconnection11.1 V / 22.2 V or 11.8V / 23.6V or BatteryLife algorithm
    Reduced voltage charge reconnection13.1 V / 26,2 V or 14 V / 28 V or BatteryLife algorithm
    ProtectionBattery polarity reversal (fuse)
    Output short-circuit
    Overheating
    Operating temperature
    to +60°C (rated output power up to 40°C)
    Humidity100 %,
    non-condensing
    Maximum altitude5000 m (full rated output up to 2000 m)
    Environmental conditionsIndoor Type 1, without air conditioning
    Pollution levelPD3
    Data communication portVE.Direct or Bluetooth
    CASING
    ColorBlue (RAL 5012)
    Power terminals
    mm² / AWG10
    Degree of protectionIP43 (electronic components)
    IP 22 (connection area)
    Weight
    .5 kg
    .6 kg
    ,65 kg
    Dimensions (h x w x d)100 x 113 x 40 mm100 x 113 x 50 mm100 x 113 x 60 mm
    NORMES
    SafetyEN/IEC 62109-1
    ) If a higher PV power is connected, the controller will limit the input power
    1b) The PV voltage must exceed Vbat + 5 V for the controller to switch on.
    Thereafter, the minimum PV voltage must be Vbat + 1 V.
    2) A higher short-circuit current could damage the controller in the event of reversed polarity of the PV field.

    10059
    98 Items

    Data sheet

    Charging power
    10A
    15A
    20A

    Specific References

    UPC
    712971136236
    EAN13
    0712971136236
    New